57
Parameters are split into the following groups:
■
"General"
■
"Fuel cell"
Tap the following buttons:
1.
2.
"Service"
3.
Enter password "viservice".
4. "System configuration"
5.
Select group.
6.
to select parameter.
7.
at the required parameter
8.
for the required value in line with the tables
below.
9.
to confirm
General
Note
Parameter values in
bold
are factory settings.
508.0 "UTC time zone"
Setting
Explanations
Setting of the UTC time zone in which the appliance is
located.
2
The factory setting is UTC +1 h
–
24 to +24 Time difference adjustable from
–
12 h to +12 h in in-
crements of 0.5 h
912.0 "Automatic summer/wintertime changeover"
Setting
Explanations
No
0
Automatic changeover disabled
Yes
1
Automatic changeover enabled
912.1 "Earliest day of changeover from winter to summertime"
Setting
Explanations
25
Changeover from 02:00 h to 03:00 h occurs on the
Sunday after or on this set date.
1 to 31
Day of changeover adjustable from 1st to 31st of the
month
912.2 "Month of changeover from winter to summertime"
Setting
Explanations
3
Month of changeover: March
1 to 12
Month of changeover adjustable from January to De-
cember
912.3 "Earliest day of changeover from summer to wintertime"
Setting
Explanations
25
Changeover from 03:00 h to 02:00 h occurs on the
Sunday after or on this set date.
1 to 31
Day of changeover adjustable from 1st to 31st of the
month
System configuration (parameters)
Calling up parameters
5839343
Parameter
Содержание E00T