22
■
The condensate hose and safety valve discharge
pipe are separate pipes. The pipes meet the temper-
ature requirements for CE certification.
■
We recommend connecting the condensate hose
and the safety valve discharge pipe internally via a
common drain pipe to the domestic waste water sys-
tem, either directly or via a tundish.
■
If the common drain pipe is routed outside the build-
ing, use a pipe with at least
7
30 mm and protect
this pipe from frost. Avoid long external pipe runs.
!
Please note
If the condensate hose, safety valve discharge
pipe or common drain pipe freezes, this can
result in faults and damage to the appliance.
Always protect all drain/condensate pipes
against frost.
■
Observe local building regulations.
Observe local waste water regulations.
Note
Fill the trap with water before commissioning.
Aligning the appliance
1.
2.
SW17
3.
A
Fig. 11
3.
Bring the Vitotronic control unit into the mainte-
nance position (see Fig. 53, page 102) and align
the side panels using screws
A
.
Installation sequence
Condensate connection
(cont.)
5678 044 GB
Installation
Содержание D2RA
Страница 34: ...34 1 3 4 2 2x 5 5 Fig 24 Installation sequence Fitting the front panels 5678 044 GB Installation ...
Страница 113: ...113 Maintenance Checking the Vitotronic 200 H accessories cont 5678 044 GB Maintenance ...
Страница 126: ...126 0004 0002 0004 0002 0001 0001 0002 0004 0002 0003 Fig 79 Parts lists Sorption module 5678 044 GB Components ...
Страница 133: ...133 Parts lists Sorption module hydraulics cont 5678 044 GB Components ...
Страница 136: ...136 0001 0002 0003 0004 0005 Fig 83 Parts lists Miscellaneous 5678 044 GB Components ...
Страница 163: ...163 5678 044 GB ...