91
Heating flow
Flow, DHW cylinder
Return, secondary circuit (heat-
ing return and DHW cylinder re-
turn)
+
Primary circuit return (heat
pump brine outlet)
Flow, primary circuit (heat
pump brine inlet)
A
Condenser
B
Evaporator
C
Flow temperature sensor, primary
circuit (heat pump brine inlet)
D
Low pressure Schrader valve
E
High pressure Schrader valve
F
Instantaneous heating water heater
(accessories)
G
Primary pump (accessory for
type BW 351.A07)
I
Electronic expansion valve EEV
J
Compressor
K
Flow temperature sensor, secon-
dary circuit
L
Secondary circuit return tempera-
ture sensor
M
Drain valve on the secondary side
N
Circulation pump for cylinder heat-
ing (accessory for
type BW 351.A07, installation out-
side the heat pump) with check
valve
O
Secondary pump (accessory for
type BW 351.A07, installation out-
side the heat pump) with check
valve
P
Air vent valve, secondary side
Q
Low pressure sensor EEV
R
Suction gas temperature sensor
S
Safety high pressure switch
T
High pressure sensor EEV
U
Filter dryer
V
Primary circuit return temperature
sensor (heat pump brine outlet)
W
Drain valve, primary side
X
Hot gas temperature sensor
y
Liquid gas sensor
Draining the heat pump on the primary/secondary side
1.
Shut off the connection to the heating
network.
2.
Drain heat pump at drain valve on pri-
mary/secondary side (see page 89).
Checking the sensors
Sensor connections to the controller and
sensor PCB: See page 36.
Sensor locations in the heat pump: See
diagram on page 89.
Troubleshooting
Repairs
(cont.)
5546 273 GB
Service