20
Minimum clearances for 1-stage (type BW/
BWC 301.B)
≥
400
≥
1500
A
B
Fig. 14
A
Subject to on-site installation and site conditions
B
■
Without AC-Box:
≥
100 mm
■
With AC-Box (accessories, for installation to the
left of the heat pump):
≥
400 mm (plus width of the AC-Box)
Note
■
Observe clearances for installation and mainte-
nance.
■
Additional strain relief clamps are required for the
power cables if the clearance behind the heat pump
is more than 80 mm.
Minimum clearances for 2-stage (type BW 301.B +
BWS 301.B)
≥
100
≥
400
A
≥
1500
B
Fig. 15
A
Subject to on-site installation and site conditions
B
■
Without AC-Box:
≥
100 mm
■
With AC-Box (accessories, for installation to the
left of the heat pump):
≥
400 mm (plus width of the AC-Box)
Note
■
Observe clearances for installation and mainte-
nance.
■
Additional strain relief clamps are required for the
power cables if the clearance behind the heat pump
is more than 80 mm.
Information on the use of accessories for a heat-
ing/cooling circuit or separate cooling circuit
AC-Box for active cooling function
■
The AC-Box can only be used up to a rated heating
output of
≤
17.6 kW. For higher rated heating out-
puts, install all the components required on site (with
correspondingly sized plate heat exchanger) for the
heating/cooling circuit or the separate cooling circuit.
NC-Box for natural cooling function
■
The NC-Box can only be used up to a rated heating
output of
≤
16 kW. For higher rated heating outputs,
install all the components required on site (with cor-
respondingly sized plate heat exchanger) for the
heating/cooling circuit or the separate cooling circuit.
■
In 2-stage heat pumps, the NC-Box
cannot
be
installed immediately above the heat pump. The
hydraulic connection lines between heat pump
stage 1 and heat pump stage 2 are installed above
the heat pumps.
Preparing for installation
Siting and transport requirements
(cont.)
5516461
Installation
Содержание BW 301.B06
Страница 69: ...69 Fig 49 Maintenance Opening the casing door 5516461 Maintenance...
Страница 76: ...76 Maintenance Condensation and moisture in the heat pump cont 5516461 Maintenance...
Страница 79: ...79 Parts lists type BWC 301 B Parts not shown type BWC 301 B cont 5516461 Components...
Страница 88: ...88 Parts lists type BWC 301 B Hydraulics type BWC 301 B cont 5516461 Components...
Страница 91: ...91 Parts lists type BW 301 B Parts not shown type BW 301 B cont 5516461 Components...
Страница 100: ...100 Parts lists type BW 301 B Hydraulics type BW 301 B cont 5516461 Components...
Страница 103: ...103 Parts lists type BWS 301 B Parts not shown type BWS 301 B cont 5516461 Components...