40
Note
Permissible cylinder temperatures:
■ Top section:
Max. 50 °C
■ Average cylinder temperature:
45 °C
■ Exception BW 302.A090 /
BW 302.A120 top section:
Max. 60 °C
Size the plate heat exchanger
eR
in
accordance with the technical guide.
Electrical installation scheme
For a summary of electrical connections,
see from page 53 and separate "Con-
nection and wiring diagram".
Required parameter settings for DHW heating
Set the required parameters during com-
missioning; see from page 83.
Parameter
Setting
"System definition"
■
"System scheme 7000"
"0"
/
"2"
/
"4"
/
"6"
/
"8"
/
"10"
DHW heating:
"Time program DHW"
Set time program (see op-
erating instructions)
"Time prog. DHW circ."
Set time program (see op-
erating instructions)
"DHW"
■
"Enable booster heaters for DHW heating 6014" "1"
■
"Enable electric heaters for DHW heating 6015"
"1"
"External heat source"
■
"Enable external heat source for DHW heating
7B0D"
"0"
Preparing for installation
DHW heating
(cont.)
5848 164 GB