46
The control unit must be matched to the system equip-
ment level.
■
To do this, select the relevant system scheme (see
the following diagrams).
■
Set the codes according to the accessories fitted:
Accessories installation and service instruc-
tions
Note
Various system components are recognised automati-
cally by the control unit and the relevant codes are
adjusted automatically.
For individual coding steps, see page 55.
System version 1
One heating circuit without mixer A1
4
3
1
2
Fig. 40
1
Vitodens 222-F
2
Outside temperature sensor (only for weather-
compensated control units)
3
Vitotrol 100 (only for constant temperature control
units)
4
Heating circuit without mixer A1 (heating circuit 1)
Function/system components
Code
Settings
Group
Operation with LPG
82:1
"General"
/
1
System
with
DHW circulation pump:
DHW circulation pump connected at internal H1 or H2 extension
—
—
Commissioning, inspection, maintenance
Matching the control unit to the heating system
5773 216 GB
Содержание B2TA
Страница 12: ...12 2 5 1 4 2x 3 Fig 5 Installing the boiler Removing the front panels 5773 216 GB Installation ...
Страница 13: ...13 1 2 SW17 Fig 6 Installing the boiler Siting and levelling the boiler 5773 216 GB Installation ...
Страница 23: ...23 4 1 5 2 2x 3 Fig 16 Installing the boiler Fitting the front panels 5773 216 GB Installation ...
Страница 101: ...101 Parts lists Overview of assemblies 5773 216 GB Components ...
Страница 107: ...107 Parts lists Hydraulics 5773 216 GB Components ...
Страница 118: ...118 0004 0002 0005 0006 0001 0003 Fig 77 Parts lists Miscellaneous 5773 216 GB Components ...
Страница 142: ...142 5773 216 GB ...
Страница 143: ...143 5773 216 GB ...