16
4.
Note
Only remove the clip under the gas pipe union nut
once the appliance has been installed. Clip is no
longer required.
5.
Tighten union nuts so that they form a tight seal.
Torque settings:
■
Union nuts G
¾
: 30 Nm
■
Union nuts G
½
: 24 Nm
When carrying out any work on gas connection fit-
tings, counterhold with a suitable tool. Never trans-
fer any forces to the internal components.
6.
Tighten locking ring fittings so that they form a tight
seal:
One turn beyond finger-tight.
Fitting the boiler to the wall mounting bracket
Note
Various installation components can be found in a sep-
arate pack. Keep the installation components safe, as
they will be required for later installation.
Installation sequence
Mounting the boiler and making connections
(cont.)
5593201
Installation
Содержание B2HF
Страница 33: ...33 2 2x 1 Fig 26 Installation sequence Closing the wiring chamber 5593201 Installation ...
Страница 45: ...45 1 2x 1 2 3 2x 2 3 Fig 32 Commissioning inspection maintenance Removing the front panel 5593201 ...
Страница 111: ...111 1 2 4 3 6 5 Fig 56 Troubleshooting Repairs cont 5593201 Diagnosis ...
Страница 134: ...134 WiFi router 31 Wiring diagram 121 Keyword index Keyword index cont 5593201 ...
Страница 135: ...135 5593201 ...