57
Power supply with power-OFF
Power-OFF without on-site load disconnection
The power-OFF signal is connected
directly to the heat pump control unit.
The compressor is "forced" off when
power-OFF is enabled.
Parameter
"Output for instant. heating
water heater at power-OFF 790A"
determines whether and at what stage
the instantaneous heating water heater
stays operational during power-OFF.
Note
Observe the technical connection condi-
tions of the relevant power supply util-
ity.
X3.7
X3.6
3
3
4
4
3
3/N
3/N
≈
4
kWh
kWh
5
3
(400 V~)
7 (230 V~)
X3.18/X2.1/X1.1
Diagram excluding fuses and RCD.
A
Heat pump control unit (internal unit,
luster terminals, see chapter "Over-
view of connections: Internal unit")
B
Instantaneous heating water heater
C
Heat pump compressor (external
unit)
D
Heat pump control unit power sup-
ply (see chapter "Heat pump control
unit power supply (230 V~)")
E
High tariff meter
F
Backup fuse ripple control receiver
G
Ripple control receiver (contact
open: power-OFF enabled)
Feed: TNC system
H
Economy tariff meter
K
Feed: TNC system
Installation sequence
Power supply
(cont.)
5782 201 GB
Installation
Содержание AWT-AC 221.A04
Страница 18: ...18 10 9 11 Installation sequence Installing the internal unit cont 5782 201 GB ...
Страница 20: ...20 2x 4x 6x 4x 22 21 20 19 Installation sequence Installing the internal unit cont 5782 201 GB ...
Страница 88: ...88 Removing cover from programming unit if necessary 5 4 4x Troubleshooting Repairs cont 5782 201 GB ...
Страница 102: ...102 0006 0003 0005 0001 0007 0008 0002 0004 0010 0009 Parts lists internal unit Internal unit casing cont 5782 201 GB ...
Страница 155: ...155 5782 201 GB ...