121
Heat pump cascade
Cascade via external extension H1
Parameter
Setting
Lead heat pump
Lag heat pump
"System definition"
Ó
"System scheme 7000"
"0"
to
"10"
"11"
"System definition"
Ó
"External extension 7010"
"1"
"0"
"System definition"
Ó
"Cascade control 700A"
"1"
"0"
"System definition"
Ó
"Number of lag heat pumps in
cascade 5735"
"1"
to
"3"
–
"System definition"
Ó
"Output lag heat pump 700B"
"0"
to
"255"
–
"System definition"
Ó
"Use of heat pump in cascade
700C"
"0"
to
"15"
–
"System definition"
Ó
"Flow temperature for external
demand 730C"
–
"0"
to
"700"
(
≙
0 to 70 °C)
Cascade via LON
Parameter
Setting
Lead heat pump
Lag heat pump
"System definition"
Ó
"System scheme 7000"
"0"
to
"10"
"11"
"System definition"
Ó
"Cascade control 700A"
"2"
"0"
"System definition"
Ó
"Number of lag heat pumps in
cascade 5735"
"1"
to
"4"
–
"System definition"
Ó
"Output lag heat pump 700B"
"0"
to
"255"
–
"System definition"
Ó
"Use of heat pump in cascade
700C"
"0"
to
"31"
"0"
to
"31"
Commissioning, inspection, maintenance
Further details regarding the individual steps
(cont.)
5609 667 GB
Service
Содержание 7452609
Страница 68: ...68 Removing the top panel 1 Installation sequence Siting the heat pump cont 5609 667 GB...
Страница 125: ...125 Opening the casing door Troubleshooting Maintenance cont 5609 667 GB Service...
Страница 145: ...145 0017 0015 0012 0016 0013 0023 0022 0014 0024 Parts lists Electrical equipment type BWS cont 5609 667 GB Service...
Страница 183: ...183 5609 667 GB...