54
Hardware Set-Up Procedures
IM-HC 599871 0321 RABS
X
Briefly press the button “+” or “-”.
Z
The current room temperature (actual temperature) is indicated.
X
Keep the button “+” or “-” pressed until the bottom LED emits light.
X
Set the target temperature by pressing the buttons “+” and “-”
Z
The new setting is adopted after 3 s — after 5 s, the LED goes
out.
You can also set the room temperature via the operating software.
6.1.4 “Rooms / Thermostat Menu” on page 75
The setting range of the thermostat may be restricted by the
operating software.
Ä
6.1.7 “Limit Rooms / Room Temperature Menu” on page
4.5.2 Changing the Temperature Units
The temperature can be displayed in °F or °C. When temperature units
are changed, all thermostats and the operating software adopt the
change.
Temperature units are preset to Fahrenheit in delivery state.
X
Keep the “+” and “-” buttons pressed for five seconds.
Z
The display indicates F (°F) or C (°C).
X
Change the units with the “+” or “-” button
Z
The new setting is adopted after 3 s — after 5 s, the LED goes
out.
To reset the units in the operating software, see
Settings / Country-Specific Settings Menu” on page 87
4.6 Resetting to Factory Settings
–
Reset
When you log in thermostats to control units, the system uniquely
assigns the log-in information to each other. This ensures that the
communication data of other devices in the vicinity is ignored.
You can move previously assigned devices to another location, but you
must reset them first. This resets the devices to their delivery state
(factory settings).
A reset is also possible if the control behaves differently than described
in the instructions (program crash).