background image

Viega LLC

585 Interlocken Blvd.

Broomfield, CO 80021

Phone (800) 976-9819

www.viega.us

Product Instructions

Viega PureFlow Press 

Zero Lead Bronze Fittings

PI-PF 520740 0621 PureFlow Press Zero Lead Bronze (EN ES FR)

EN

Product Instructions

Viega PureFlow Press Zero Lead 

Bronze Fittings

This document is subject to updates. For the most current Viega 

technical literature please visit www.viega.us.

Pure

Flow

1/2”

Pure

Flow

1/2”

6

Pure

Flow

1/2”

1

6

7

2

8

10

3

9

11

4

5

EN

Viega PureFlow Press

Zero Lead Bronze Fittings

Viega products are designed to be 

installed by licensed and trained plumbing 

and mechanical professionals who are 

familiar with Viega products and their installation.

 

Installation by non-professionals may void 

Viega LLC’s warranty.

The tool locator ring must be in the factory 

installed position while making a press to 

ensure a consistent leakproof connection. 

It may be necessary to rotate the tool locator ring 

to avoid interference between the ring and tool.

The tool locator ring must be in the factory 

installed position while making a press to 

ensure a consistent leakproof connection. 

It may be necessary to rotate the tool locator ring 

to avoid interference between the ring and tool.

Zero Lead identifies Viega

®

 products meeting 

the lead free requirements of NSF 61-G 

through testing under NSF/ANSI 372 (0.25% 

or less maximum weighted average lead content).

1

  Square off tubing to proper length. Uneven, 

jagged, or irregular cuts will produce unsatisfactory 

connections.

2

  Insert PureFlow Press fitting with attached sleeve 

into tubing and engage fully.

3

  Ensure full tubing insertion at view holes in 

attached press sleeve. Full insertion means tubing 

must be completely visible in at least two view 

holes and partially visible in the one. 

 

If using a hand tool continue with steps 4 to 7. If 

using a power tool continue with steps 8 to 11.

4

  Position the PureFlow press tool perpendicular 

over the press sleeve, resting it against the tool 

locator ring. Make sure the PureFlow press tool is 

properly aligned (see step 6 figure if it is not).

5

  Close handles, using trigger to reduce grip span if 

desired.

6

  If the PureFlow press tool is not properly aligned 

with the locator ring, use the emergency release 

(using a screw driver to turn the emergency 

release) to open the press tool. Once released, 

align the PureFlow press tool properly and go 

back to step 4.

WARNING!

 

The connection is not leakproof when 

the tool has been opened by emergency 

release. The tool locator ring must be present to 

ensure a proper PureFlow Press connection.

7

  Extend the PureFlow press tool handle and 

continue ratcheting until automatic tool release 

occurs at the proper compression force.

8

  If using a power tool, insert the appropriate 

PureFlow Press Jaw into the press tool and push 

in the holding pin until it locks.

9

  Open jaw and position perpendicular over press 

sleeve resting it against the tool locator ring.

CAUTION!

 

Do not press twice.

CAUTION!

 

Do not press twice.

10

  Start the pressing process; hold the trigger until 

the jaw has automatically released.

11

  When press connection is complete, open and 

remove the jaw.

WARNING!

 

The tool locator ring must be present 

to ensure a proper PureFlow Press 

connection.

ES

Instrucciones del producto

Accesorios Viega PureFlow Press 

de bronce Zero Lead

Este documento está sujeto a actualizaciones. Para obtener la 

documentación técnica más reciente de Viega, visite www.viega.us.

FR

Instructions produit

Raccords en bronze Viega PureFlow 

Press Zero Lead

Le présent document est soumis à des mises à jour. Pour consulter les 

manuels techniques Viega les plus récents, veuillez visiter www.viega.us.

Отзывы: