background image

Wall in the urinal water pipe section.

INFO! Observe the maximum plaster thickness. 

Plaster the urinal water pipe section and tile.

3.3

Disposal

Separate the product and packaging materials (e. g. paper, metal,

plastic or non-ferrous metals) and dispose of in accordance with valid

national legal requirements.

N

N

Handling

Prevista Pure urinal water pipe section

13 from  13

Содержание Prevista Pure 8566

Страница 1: ...nals with concealed flushing system urinal flush plates for Prevista manual and touchless flush actuation Model Year built 8566 from 06 2019 en_INT Prevista Pure urinal water pipe section Instructions for Use ...

Страница 2: ...Prevista Pure urinal water pipe section 2 from 13 ...

Страница 3: ... 6 2 1 Standards and regulations 6 2 2 Intended use 6 2 2 1 Areas of use 6 2 3 Product description 7 2 3 1 Overview 7 2 3 2 Technical data 7 3 Handling 8 3 1 Assembly information 8 3 1 1 Mounting conditions 8 3 1 2 Installation dimensions 9 3 2 Assembly 10 3 2 1 Assembly 10 3 3 Disposal 13 Table of contents Prevista Pure urinal water pipe section 3 from 13 ...

Страница 4: ...o possible operating instructions The installation of Viega products must take place in accordance with the general rules of engineering and the Viega instructions for use 1 2 Labelling of notes Warning and advisory texts are set aside from the remainder of the text and are labelled with the relevant pictographs DANGER This symbol warns of possible life threatening injury WARNING This symbol warns...

Страница 5: ...many e g DIN DVGW Some passages in the text may refer to technical codes in Europe Germany These should serve as recommendations in the absence of corresponding national regulations The relevant national laws stand ards regulations directives and other technical provisions take priority over the German European directives specified in this manual The information herein is not binding for other cou...

Страница 6: ...e Notice Regulations applicable in Ger many Flush flow DIN 3265 Noise class DIN 4109 2 2 Intended use 2 2 1 Areas of use The Prevista Pure urinal water pipe section is a universal compact design shell casing for urinals with concealed flushing systems and for urinal flush plates for Prevista manual and touchless flush actuation Product information Prevista Pure urinal water pipe section 6 from 13 ...

Страница 7: ...g voltage 230 V 50 Hz infrared 230 V Magnetic coil 6 V Flow pressure 0 05 0 5 MPa 0 5 5 bar Calculated flow 0 3 l s Flush flow see Ä Regulations from section Technical data on page 6 0 3 0 7 l s Noise class see Ä Regulations from section Technical data on page 6 2 Product information Prevista Pure urinal water pipe section 7 from 13 ...

Страница 8: ...ce with manufacturer s documentation urinal ceramic C in accordance with manufacturer s documentation urinal ceramic D in accordance with manufacturer s documentation urinal ceramic E in accordance with manufacturer s documentation urinal ceramic X upper edge of the finished floor Y min 40 mm Installation dimensions Handling Prevista Pure urinal water pipe section 8 from 13 ...

Страница 9: ...Location diagram for power pack terminals battery and control 3 1 2 Installation dimensions 3 3 JO BY Fig 2 Dimensional drawing Handling Prevista Pure urinal water pipe section 9 from 13 ...

Страница 10: ... electrics may only be carried out by trained electricians Switch off the mains voltage before carrying out work on electrical parts INFO The distance from the box to the sanitary object must be at least 40 mm Determine and mark the fixing points Drill the holes and insert the dowels NJO NN Handling Prevista Pure urinal water pipe section 10 from 13 ...

Страница 11: ... water pipe section to the wall Connect the water pipeline to the urinal water pipe section inlet Install the water pipeline from the urinal water pipe section up to the sanitary object Handling Prevista Pure urinal water pipe section 11 from 13 ...

Страница 12: ... tricians Always de energise the connection cable before work is com menced Once the product has been mounted and commissioned hand over this manual to the operator For infrared actuation insert the cable laid by the customer into the casing of the urinal water pipe section Insulate the pipe Replace the site protection Screw the seal plug in Handling Prevista Pure urinal water pipe section 12 from...

Страница 13: ... Plaster the urinal water pipe section and tile 3 3 Disposal Separate the product and packaging materials e g paper metal plastic or non ferrous metals and dispose of in accordance with valid national legal requirements NN Handling Prevista Pure urinal water pipe section 13 from 13 ...

Отзывы: