background image

Product

Instructions

PI-MPG 561108 0518 (MegaPress G) (EN ES FR)

1 of 2

Viega LLC, 12303 Airport Way, Ste. 395 • Broomfield, CO 80021 • Ph: 800-976-9819 • Fax: 800-976-9817

This document subject to updates. For the most current Viega technical literature please visit www.viega.us.

Viega products are designed to be installed by licensed and trained plumbing and mechanical professionals who are familiar  
with Viega products and their installation. 

Installation by non-professionals may void Viega LLC’s warranty. 

Viega MegaPress

®

G

  1.  Cut piping at right angles using displacement type cutter.

  2.  Keep end of piping a minimum of 4" away from the contact area 

of the vise to prevent possible damage to the piping in the press 

area. See MegaPress Manual for minimum clearance required 

for prep tools.

  3.  Remove burr from inside and outside of piping and prep to 

proper insertion depth using a preparation tool or fine grit 

sandpaper.

  4.  Check seal and grip ring for correct fit. Do not use oils or 

lubricants.

  5.  Illustration demonstrates proper fit of grip ring, separation ring 

and sealing element.

  6.  Mark proper insertion depth. Improper insertion depth may result 

in an improper seal. The depth marking shall be visible on the 

completed assembly.

 7a.  Viega MegaPress ½" - 1" fitting connections must be performed 

with MegaPress Jaws. See RIDGID Operator’s Manual for proper 

tool instructions.

 7b.  Open the MegaPress Jaw and place at right angles on the 

fitting. Visually check insertion depth using mark on piping.

 7c.  Start pressing process and hold the trigger until the jaw has 

engaged the fitting. Keep extremities and foreign objects away 

from MegaPress Jaw during pressing operation to prevent injury 

or incomplete press. 

 8a.  Viega MegaPress 1¼" - 2" fitting connections must be 

performed with MegaPress Rings and V2 Actuator. See 

Operator’s Manual for proper tool instructions.

 8b.  Open MegaPress Ring and place at right angles on the fitting. 

MegaPress Ring must be engaged on the fitting bead. Check 

insertion depth. 

 8c.  Place V2 Actuator onto MegaPress Ring and start pressing 

process. Hold the trigger until the Actuator has engaged the 

MegaPress Ring. Keep extremities and foreign objects away 

from MegaPress Ring and V2 Actuator during pressing operation 

to prevent injury or incomplete press. 

  9.  Remove MegaPress Jaw from fitting or release V2 Actuator from 

RIDGID MegaPress Ring and then remove MegaPress Ring 

from the fitting on completion of press.   Remove control label to 

indicate press has been completed.

Note:

 The installation, inspection, testing and purging of the fuel 

gas system shall be in accordance with local codes or, in the 

absence of local codes, in accordance with the International 

Fuel Gas Code, NFPA 54/National Fuel Gas Code z223.1, 

the Uniform Plumbing Code, NFPA 58 or CSA B 149.1 as 

applicable.

Caution:

  (a)  The fittings are for use with fuel gases and are intended for the 

operating pressure 0-125 psi.

  (b)  The fuel gas system shall not be used as a grounding electrode 

for an electrical system.

1

2

8A

7A

4

3

5

7C

8C

7B

6

8B

9

d

10

Pipe Diameter

Diàmetro del Tubo

Diamètre du Tuyau

d

(in)

d

(mm)

½"

3

16

5

¾"

3

16

5

1"

3

16

5

1¼"

10

1½"

10

2"

10

Отзывы: