background image

for concealed cistern 2H, concealed cistern 2L, concealed cis-
tern 2C, concealed cistern Standard 2S

Model

Year built:

8326.1

from  01/2011

en_INT

Flush plate Visign for Public 1

Instructions for Use

Содержание 8326.1

Страница 1: ...for concealed cistern 2H concealed cistern 2L concealed cis tern 2C concealed cistern Standard 2S Model Year built 8326 1 from 01 2011 en_INT Flush plate Visign for Public 1 Instructions for Use ...

Страница 2: ...Flush plate Visign for Public 1 2 from 20 ...

Страница 3: ...2 2 1 Overview 7 2 2 2 Technical data 7 3 Handling 8 3 1 Assembly information 8 3 1 1 Required material and tools 8 3 2 Assembly 8 3 2 1 Prepare cistern 8 3 2 2 Mount flush actuation 14 3 2 3 Mounting the flush plate 17 3 3 Commissioning 19 3 3 1 Setting the flush 19 3 4 Error faults and remedy 19 3 5 Care and maintenance 20 3 5 1 Maintenance tips 20 3 6 Disposal 20 Table of contents Flush plate V...

Страница 4: ...not extend to possible operating instructions The installation of Viega products must take place in accordance with the general rules of engineering and the Viega instructions for use 1 2 Labelling of notes Warning and advisory texts are set aside from the remainder of the text and are labelled with the relevant pictographs DANGER This symbol warns against possible life threatening injury WARNING ...

Страница 5: ...nd or in Germany e g DIN DVGW Some passages in the text may refer to technical codes in Europe Germany These should serve as recommendations in the absence of corresponding national regulations The pertinent national laws stand ards regulations and guidelines as well as other technical guidelines have priority over German European guidelines in this manual The information is not binding for other ...

Страница 6: ...n model 2L Ascertain which model is installed before mounting The following infor mation will help you to determine the model of the cistern installed Cistern 2H The revision shaft of this cistern is found at a height of approx 1 metre on the front Cistern 2L The revision shaft of this cistern is either found at a height of approx 75 cm on the front or on the top Suitable cisterns Product informat...

Страница 7: ... 5 threaded bolt 2 2 2 Technical data The product exhibits the following technical data A flush with the large flush volume is always released via the flush plate The flush volume is approx 6 9 litres For the setting of the flush see Ä Chapter 3 3 1 Setting the flush on page 19 Flush volume Product information Flush plate Visign for Public 1 7 from 20 ...

Страница 8: ...ewdriver T 10 n knife cutter 3 2 Assembly 3 2 1 Prepare cistern The following work stages and diagrams differ depending on the cistern being used The relevant steps are marked accordingly Requirements n The cistern is fitted into the front wall n The front wall is tiled Cut into shaft cover Tool Handling Flush plate Visign for Public 1 8 from 20 ...

Страница 9: ...is so that the cut is made flush to the surface of the wall Cut the corners of the revision shaft vertically through to the wall surface Bend out and pull down the sides of the revision shaft The edge of the revisions shaft must be flush with the wall surface Handling Flush plate Visign for Public 1 9 from 20 ...

Страница 10: ...front of cistern 2L Press the bow backwards from the mounting of the mechanism INFO Only for assembly of the flush plate on the top of cistern 2L Press the bow backwards from the mounting of the mechanism Turn the mechanism s lock by 90 in an anti clockwise direction ð The mechanism is unlocked and can be removed Handling Flush plate Visign for Public 1 10 from 20 ...

Страница 11: ...vision shaft is shortened in such a way that it is flush with the surface n Mechanism has been removed Close corner valve Loosen flexible hose on the filling valve SW 19 Flush pipelines cistern 2H Handling Flush plate Visign for Public 1 11 from 20 ...

Страница 12: ...pen the corner valve for a few seconds to rinse the pipe Re close corner valve Connect the flexible hose onto the filling valve SW 19 Open corner valve Handling Flush plate Visign for Public 1 12 from 20 ...

Страница 13: ... the upper edge of the tiles n Mechanism has been removed Close corner valve Loosen flexible hose on the filling valve SW 19 Open the corner valve for a few seconds to rinse the pipe Re close corner valve Flush pipelines cistern 2L Handling Flush plate Visign for Public 1 13 from 20 ...

Страница 14: ...e flexible hose onto the filling valve Open corner valve 3 2 2 Mount flush actuation Hang the mechanism in the bow of the drain valve Mount mechanism cistern 2H Handling Flush plate Visign for Public 1 14 from 20 ...

Страница 15: ...nds on whether the flush plate is to be fitted to the front or top of the cistern Vertical installation flush plate on the front of the cistern Horizontal installation flush plate on the top of the cis tern Hang the mechanism in the bow of the drain valve Mount mechanism cistern 2L Vertical installation flush plate on the front of the cistern Handling Flush plate Visign for Public 1 15 from 20 ...

Страница 16: ...es in the cistern Turn the mechanism s lock by 90 in a clockwise direction ð The mechanism is locked Hang the mechanism in the bow of the drain valve Horizontal installation flush plate on the top of the cistern Handling Flush plate Visign for Public 1 16 from 20 ...

Страница 17: ...e in the indentations in the revision shaft of the cistern Turn the mechanism s lock by 90 in a clockwise direction ð The mechanism is locked 3 2 3 Mounting the flush plate Requirements n The flush actuation has been mounted Re mount cistern casing Handling Flush plate Visign for Public 1 17 from 20 ...

Страница 18: ...x 15 mm behind the upper edge of the tiles Secure threaded bolts with a 90 turn Screw actuating rod into the tapped hole Set the screw in depth flush with the upper edge of the tiles with the help of the template supplied Screw on basic panel Handling Flush plate Visign for Public 1 18 from 20 ...

Страница 19: ...rge flush volume approx 6 9 litres 3 4 Error faults and remedy Error Cause Remedy WC does not flush Cistern is not yet completely full Wait until the cistern is sufficiently full No water in cistern corner valve is closed Open corner valve WC flush runs through Dirty seal in filling valve Check seal replace if necessary Handling Flush plate Visign for Public 1 19 from 20 ...

Страница 20: ...ime scale on the flush plate Under no circumstances should scouring agent or scratching objects be used Strong stains can be removed using typical household cleaner Rinse the detergent thoroughly with clear water after the prescribed exposure time There should be no residue on the components 3 6 Disposal Separate the product and packaging materials e g paper metal plastic or non ferrous metals and...

Отзывы: