Model
Year built:
6163.2
from 06/2015
en_INT
Multiplex drain/overflow functional unit
Instructions for Use
Страница 1: ...Model Year built 6163 2 from 06 2015 en_INT Multiplex drain overflow functional unit Instructions for Use...
Страница 2: ...Multiplex drain overflow functional unit 2 from 17...
Страница 3: ...sories 8 3 Handling 10 3 1 Assembly information 10 3 1 1 Mounting conditions 10 3 1 2 Installation dimensions 10 3 1 3 Required tools and materials 10 3 2 Assembly 11 3 2 1 Mounting overflow 11 3 2 2...
Страница 4: ...does not extend to possible operating instructions The installation of Viega products must take place in accordance with the general rules of engineering and the Viega instructions for use 1 2 Labell...
Страница 5: ...in Germany e g DIN DVGW Some passages in the text may refer to technical codes in Europe Germany These should serve as recommendations in the absence of corresponding national regulations The pertine...
Страница 6: ...dour trap for bathtubs with a 52 mm drain hole The drain overflow is suitable for extra long bathtubs Detailed information regarding all bathtub models and the corre sponding Viega drains overflows ca...
Страница 7: ...9 pipe extension 10 overflow pipe 11 Bowden cable 12 sleeve 13 overflow unit 14 profile seal 15 O ring 16 fixing flange 2 2 2 Technical data Drainage capacity at an accumu lation height of 300 mm 0 8...
Страница 8: ...must be purchased separately Equipment sets As this product is a the functional unit without rotatable rosette and valve cone you require an equipment set to enable complete mounting Equipment sets c...
Страница 9: ...e a valve cone a fixing screw a flange cover and a mounting aid for the drain of the functional unit Equipment set Multiplex Visign M9 Model 6171 0 Multiplex extension set It is possible to extend the...
Страница 10: ...ble 3 1 2 Installation dimensions Fig 2 Dimensional drawing The following values are valid for L length and H height L 100 680 H 180 480 3 1 3 Required tools and materials The following tools are requ...
Страница 11: ...f the overflow pipe Place the O ring in the annular gap of the fixing flange Hold the overflow unit on the overflow opening of the bathtub from the outside Screw the fixing flange into the overflow un...
Страница 12: ...ole Fit the valve top in the double seal INFO The cross shaped structures of the drain units and the valve top must be positioned parallel on top of each other to ensure the full drainage capacity Pla...
Страница 13: ...f the overflow unit parallel to the overflow pipe and mark the positions where the drain and the overflow should be con nected Maintain an insertion depth of at least 15 mm Cut the overflow pipe to th...
Страница 14: ...he drain elbow Screw the union nut on the drain unit Align the odour trap in such a way that the drain elbow can be con nected to the wastewater pipe Turn the drain at the joints until the required po...
Страница 15: ...cone should be 2 3 cm wide when opened If necessary regulate the width of the opening of the valve cone using the adjusting screw see next step Set the valve cone with the help of the adjusting screw...
Страница 16: ...ing agent abrasive sponges lime plaster or cement dissolver solvents or other acidic cleaning agents Normal soap or a mild cleaning agent can be used for regular care and prevention of lime scale on t...
Страница 17: ...arate the product and packaging materials e g paper metal plastic or non ferrous metals and dispose of in accordance with valid national legal requirements Handling Multiplex drain overflow functional...