6.5. Motion
Setup
Setup the general functions of Pan/Tilt motions.
Power Up Action
[ON/OFF]
Auto Flip
[ON/OFF]
Jog Speed
[FAST/NORMAL/SLOW]
The nominal jog speed is listed below when zoom is x1.
As zoom magnification is increased, the speed will be
decreased to maintain equal controllability.
FAST
160
°
/sec
NORMAL 80
°
/sec
SLOW
40
°
/sec
Jog Direction
[INVERSE/NORMAL]
If you set this to ‘Inverse’, the view in the screen moves in the same direction with jog
tilting. If ‘Normal’ is selected, the view in the screen moves in the reverse direction.
Park Action
Activate Park function.
Origin Position
Redefine particular pan position to Origin.
Alarm Define
Match the Alarm senor input to one of current Preset positions.
6.5.1. Park Action Setup
This function enables the camera to locate a specific position automatically if operator
doesn’t operate the controller for a while. The Park Time can be defined as an interval from
1 minute to 4 hours.
Park Enable
[ON/OFF]
Park Time
[1 min ~ 4 hours]
The time is displayed with "hh:mm:ss" format and you
can change this by 1 min unit.
Park Action
[Preset 1~128]
Doc # INS 20/21Z704T-PZ
Issue Date: 03/22/2007
Revision: C
Page
22
of
32