BlueSolar Pro Remote Panel
For BlueSolar PWM-Pro charge controllers 12/24V 5, 10, 20, 30A Article number SCC900300000
Страница 1: ...Manual EN BlueSolar Pro Remote Panel For BlueSolar PWM Pro charge controllers 12 24V 5 10 20 30A Article number SCC900300000 ...
Страница 2: ......
Страница 3: ...5 Full setup details 8 5 1 Main menu 8 5 2 Device Information 8 5 3 Test Operation 8 5 4 Control Parameters 9 5 5 Load Settings 10 5 6 Device Parameters 12 5 7 Device Password 12 5 8 Charge mode 12 5 9 Factory reset 12 5 10 Failure Information 13 5 11 Meter parameters 13 6 Technical Specifications 13 7 RS485 connector pinout 13 8 Dimensions 14 ...
Страница 4: ...ontroller away from rain exposure severe dust vibration corrosive gas and intense electromagnetic interference 2 Installation Please see section 8 for mounting dimensions Connection to the BlueSolar PWM Pro charge controller The panel must be connected to the controller with a standard RJ45 UTP cable ...
Страница 5: ...3 EN 3 Product features 3 1 General Warning LED Audible Alarm Communication LED Display LCD screen Buttons ...
Страница 6: ...arning indicator LED flashes in case of failure of the connected charge controller Audible alarm The audible failure alarm can be activated or deactivated Communication LED Indicates communication status when the display is connected with the charge controller ...
Страница 7: ...ery V A Load V A Day and night icons Night day If the voltage of the solar array is above 1V the daytime icon is shown Battery icon The battery icon shows the state of charge of the battery For this function the correct battery capacity must be set see section 5 4 and all loads must connected to the load output i e not directly to the battery Note When the battery is fully discharged the icon disp...
Страница 8: ...oad status icon Load output on load output off 3 3 Buttons Operation is visualized in the schematic diagram below 4 Monitoring The default monitoring display and monitoring subpages can be accessed with the UP DOWN and LEFT RIGHT buttons See the diagram on the next page ...
Страница 9: ...7 EN ...
Страница 10: ...nter or exit the corresponding pages of the menu items A password must be entered to change settings When on a settings page press OK to access the password page and fill in the password to enable changing of settings The default password is 000000 5 2 Device information The charge controller model ratings and serial number are displayed press the DOWN button to display the serial number 5 3 Test ...
Страница 11: ... 0 9 Rated voltage system voltage Auto 12V 24V Over voltage load disconnect 16 0V 9 17V Charge limit highest charge voltage including temp compensation 15 0V 9 17V Over voltage load reconnect 15 0V 9 17V Equalize charge 14 6V 14 8V 9 17V Boost charge absorption charge 14 2V 14 4V 14 6V 9 17V Float charge 13 8V 13 8V 13 8V 9 17V Boost trigger voltage starts new charge cycle 13 2V 9 17V Low voltage ...
Страница 12: ...anual Control Light On Off Light On Timer Time Control Manual Control Default ON Manual Control Light On Off Light On Timer Time Control Manual Control Light On Off Light On Timer Time Control Manual Control Light On Off Light On Timer Time Control Light On Off On 0 5V DeT 10M Off 0 4V DeT 10M Light On Timer On 0 5V DeT 10M Off 0 6V DeT 10M NightTime 12H 00M Light On Timer OnTime1 01H 00M OnTime2 ...
Страница 13: ...lt 0 40V the load output is switched off In order to prevent unwanted switching a confirmation time DeT can be set default 10 minutes range 0 99 minutes Option 3 Light On Timer This option allows for a pre set On time after dusk and a pre set Off time before dawn The dusk and dawn switching moments and confirmation time are set as under option 2 The remaining parameters are set as follows NightTim...
Страница 14: ... time use the DOWN button to go to the second screen The above data are stored in the Charge Controller 5 7 Device Password The password is needed to change settings of the charge controller The default password is 000000 The password is stored in the Charge Controller 5 8 Charge mode This page is intended for future applications Please do not change 5 9 Factory reset Allows reset of the charge co...
Страница 15: ...e monitoring pages default 0 seconds Backlight duration default 20 seconds Audible alarm ON OFF default OFF 6 Technical Specifications Self consumption backlight and acoustic alarm on max 65mA Backlight on max 23mA Backlight off max 15mA Faceplate dimensions 98 98 mm 3 86 3 86 inch Frame dimensions 114 114 mm 4 49 4 49 inch Connector type RJ45 Cable length Max 20 m Weight 0 2 Kg Ambient Temperatur...
Страница 16: ...14 8 Dimensions ...