Victory VPP Скачать руководство пользователя страница 1

INSTALLATION AND OPERATING INSTRUCTIONS

for all

VPP and VPPD Models

3779 CHAMPION BLVD, WINSTON-SALEM, NC 27105
Phone: (888) 845-9800 | Fax: (800) 253-5168 | Web: victoryrefrigeration.com

809-152A REV B 10/28/2020

SEE BACK COVER FOR  

WARRANTY REGISTRATION

Содержание VPP

Страница 1: ...ATING INSTRUCTIONS for all VPP and VPPD Models 3779 CHAMPION BLVD WINSTON SALEM NC 27105 Phone 888 845 9800 Fax 800 253 5168 Web victoryrefrigeration com 809 152A REV B 10 28 2020 SEE BACK COVER FOR W...

Страница 2: ...on reserves the right to change specifications and product design without notice Such revisions do not entitle the buyer to corresponding changes improvements additions or replacements for previously...

Страница 3: ...s There may be pinch points near the door hinges Maintenance Do NOT Clean a frozen evaporator with a sharp object Clean a dirty condenser with a sharp object Store gasoline kerosene or any other flamm...

Страница 4: ...that have been altered in any way Alterations or part substitutions will void the warranty Limitations The machine is designed for use indoors in a controlled environment It must be kept dry not overh...

Страница 5: ...5 1 2 4 5 1 3 VPPD72HC 3 72 x 37 x 53 5 1 3 4 5 1 3 VPPD72HC 4 72 x 37 x 53 5 4 4 5 1 3 VPPD72HC 6 72 x 37 x 53 5 6 4 5 1 3 VPPD93HC 2 93 x 36 5 x 55 5 2 2 7 8 1 2 120 4 23 VPPD93HC 4 93 x 36 5 x 55 5...

Страница 6: ...nches at back None at sides Floor Load the floor on which the cooler is located must be even and level free from vibrations and strong enough to support the combined weights of the unit and maximum pr...

Страница 7: ...be visible once screwed in 3 Tilt the cabinet in one direction approximately 8 and block it securely with pieces of 2x4 lumber or other suitable material 4 Thread the stem casters or legs into the 13...

Страница 8: ...on bar facing up Be careful not to dislodge clips during installation 6 Place shelves so that the retaining tab on the clip captures the shelf as shown 7 Confirm that the shelf is resting on ALL 4 cli...

Страница 9: ...ollow these instructions 1 Open the drawer to full extension 2 Push the white locking tabs forward on both sides of the drawer 3 Press down the back of the tabs 4 Slide the drawer out of the cabinet 5...

Страница 10: ...actory and should not need adjustment however if it was changed the standard setting is 38 F Cautions Care must be taken whenever moving or servicing the unit The refrigerant is contained in a sealed...

Страница 11: ...ase the melting or defrost button for a manual defrost Note Holding the defrost button in too long will shut the controller off The pans must be kept in place for proper temperature control The intern...

Страница 12: ...he Compressor is not running The Condenser Fan is wired directly to the Compressor not through the controller EVAPORATOR FAN The Evaporator Fan runs continuously in refrigerators When the unit is plug...

Страница 13: ...lease Increases Set Point Long press and release Increases display brightness DOWN Quick press and release Decreases Set Point Long press and release Decreases display brightness DEFROST ESC Quick pre...

Страница 14: ...User Manual for VPP VPPD Victory Rev 10 2020 Victory 14 Control Panel Connections Changing the Set point...

Страница 15: ...n If configured cut in alarm relay beep the buzzer Condenser alarm dor Door open for more than Always Blink dor If configured cut in alarm relay beep the buzzer Door open alarm uHi Line voltage is hig...

Страница 16: ...ter 3 Dry with a soft cloth 4 Polish with a soft cloth wiping with the grain 5 Wipe weekly with stainless steel cleaner Weekly Interior Cleaning 1 Remove all food food related items and shelves Store...

Страница 17: ...ut to release it 3 Pull grille carefully out and off the cabinet Condenser Coil 4 Examine condenser surface if dusty brush and vacuum the dust and lint from the surface of the coil Brush up and down t...

Страница 18: ...unt of cleaner Heat tint or discoloration Penny Brite or Copper Brite Past NuSteel DuBois Temp or Tarnite Revere Stainless Steel Cleaner Allen Polish Steel Bright Tenacious Deposits Rusty Discoloratio...

Страница 19: ...temp control No cooling compressor hums but does not start Low voltage to unit Compressor starting system failure Check voltage correct as needed Check start relay and start capacitor See next step No...

Страница 20: ...ree from flame or spark It must also be in a well ventilated area with a nearby open window or door A sign noting service of a system containing propane must be attached to the unit during refrigerati...

Страница 21: ...User Manual for VPP VPPD Victory Rev 10 2020 Victory 21 FOR THE SERVICE TECH WIRING DIAGRAM...

Страница 22: ...door mechanisms or freight damage are not covered by this warranty For the purpose of this warranty the original purchaser shall be deemed to mean the individual or company for whom the product was o...

Страница 23: ...EXPRESS IMPLIED OR STATUTORY INCLUDING THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE WHICH ARE HEREBY DISCLAIMED AND ALL OTHER OBLIGATIONS OR LIABILITIES ON OUR PART A...

Страница 24: ...______ Date Of Installation _________________ Cabinet Serial Number _____________________________________________ Location Of Product Business Name ____________________________________________________...

Отзывы: