02.2020
INSTRUCTION MANUAL
for installation and operation of pellet stove
VITTORIA В*
15
Meaning that through the hours from 22:00 to 23:00 it will not operate.
The arrows would change the day of the week and can set new operation times of the boiler.
Here one can access the internal settings of the
control unit. Pressing the icon displays access
panel requiring entering a password.
The settings have been restricted in four access
levels:
- The first level is Installer
- The second level is Service Technician
- The third level is Delete Errors with a
password
7777
.
- The fourth password is
2468
and serves to
unlock the display
The display can be locked in two ways. The
first one is to hold for more than 3 seconds
the Title Page Settings Icon .
The second one is automatically, while
transitioning to Standby Mode of the Display
in 10 minutes.
In case a wrong password is entered, ‘Wrong
password’ displays; it is allowed a new
attempt.
10.2.4. Installer settings.
Types of settings for Installer (entered with installer password)
Factory settings
Duration
900 sec.
Initial filling
70 sec.
Fan
250 l
Screw feeding
2 sec.
Screw Cycle
20 sec.
Temperature/ON
60
0
C
Temperature/OFF
90
0
C
Repetitions
2
Second filling
20 sec.
Duration
180 sec.
Fan
240 l
Screw feeding
3 sec.
Screw Cycle
20 sec.
Temperature difference
0 1 2 3 4
Fan / l.
210 230 240 260 280
Screw feeding / sec.
2 3 4 5 7
Screw Cycle / sec.
8 8 7 6 6
From this menu, the default language can be set:
Bulgarian,