background image

HANG THESE INSTRUCTIONS ON THE 

INSTALLED VALVE FOR FUTURE REFERENCE

 

WARNING

•  Read and understand all instructions before attempting to install, remove, adjust, or perform maintenance on any Victaulic piping products.
•  Depressurize and drain piping systems before attempting to install, remove, adjust, or perform maintenance on any Victaulic piping 

products.

•  Wear safety glasses, hardhat, and foot protection.
•  Save this installation, maintenance, and testing manual for future reference.
Failure to follow instructions and warnings could cause system failure, resulting in death or serious personal injury and property damage.

I-869E-3D

INSTALLATION, MAINTENANCE, AND TESTING MANUAL

869E-3D On-Off Deluge Valve

I-869E-3D

REV_A

Содержание 869E-3D

Страница 1: ...ore attempting to install remove adjust or perform maintenance on any Victaulic piping products Wear safety glasses hardhat and foot protection Save this installation maintenance and testing manual fo...

Страница 2: ......

Страница 3: ...g The System From Service 6 Removal Instructions 6 Operation 7 Manual Operation 7 Maintenance And Inspection Tests 8 Normal Conditions 8 Weekly Inspection 8 Monthly Inspection And Test 8 Annual Inspec...

Страница 4: ...ck injury Large and pre trimmed valves are heavy and require more than one person or mechanical lifting equipment to position and install the assembly Always practice proper lifting techniques 5 Avoid...

Страница 5: ...ion Drawing 8 7 5 1 2 3 4 Hydraulic Electric Atmosphere 6 9 System Components 1 Model 869E 3D 2 Accelerator priming restrictor 3 Check valve 4 Priming strainer 5 Manual emergency release 6 Priming lin...

Страница 6: ...applicable installation standards codes or relevant authorities 11 The deluge valve and trim must be installed only in areas where they will not be subjected to freezing temperatures 12 All initiatin...

Страница 7: ...ressure through the solenoid In the OPERATING position an electric detection system working through a control panel triggers the solenoid to release to atmosphere which then opens the HRV This causes...

Страница 8: ...HLY INSPECTION AND TEST CAUTION The system will be flooded Take all necessary precautions to drain water and prevent damage in the area protected by the deluge system 1 Complete the weekly inspection...

Страница 9: ...le causes 1 Partially plugged priming restriction Figure 1 call out 3 2 Plugged priming strainer Figure 1 call out 4 3 Leaking release system 4 Damaged deluge valve seat or a foreign object is caught...

Страница 10: ...uge Valve For complete contact information visit victaulic com I 869E 3D 8794 REV A UPDATED 10 2015 VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY AND OR ITS AFFILIATED ENTITIES IN THE UNITE...

Отзывы: