UG:121
Page 16
Specifications
Typical at 25°C, nominal line and 75% load, unless otherwise specified.
General
Number of Outputs
1 – 6
Modules
VI/E-200 and VI/E-J00: two VI/E-200s or four VI/E-J00s
Maxi: two Maxis, four Minis or six Micros
Efficiency
Typically > 75%
Safety Agency Approvals
cURus – UL 60950-1, CSA 60950-1;
cTÜVus – EN 60950-1, UL 60950-1, CSA 60950-1
CE Mark – Low Voltage Directive, 2006/95/EC
Note: certain wide temp range MI chassis will not carry all approvals
Maximum Output Power
500W at 115V
AC
, (100V
AC
minimum input)
[a]
800W at 230V
AC
, (200V
AC
minimum input)
Input
Input
85 – 264V
AC
, 47 – 500Hz
120 – 300V
DC
(derated output level)
VI-200™/VI-J00™
Line/Load Regulation
0.2% max from 10% to full load
0.5% max from no load to 10% load
Maxi/Mini/Micro
Line Regulation
[b]
0.20% max to 0.30%max
Maxi/Mini/Micro
Load Regulation
[b]
0.20% max to 0.70% max
Inrush Current
8.5A
peak @ 115V
AC
17A peak @ 230V
AC
Ride Through Time
>20ms at 500W load (nominal load)
Conducted EMI
FCC Class A
EN 55022 Class A (consult factory)
Mil-STD 461 requires external filter
Power Factor
>0.98
Transient Burst Immunity
EN61000-4-4 (consult factory)
Surge Immunity
(Common Mode & Normal Mode)
Compliant with IEC 61000-4-5, Level 3, Performance Criteria B
(Temporary loss of output power may occur which is self recoverable.)
Dielectric Withstand
Primary to Chassis GND = 2,121V
DC
Secondary to Chassis GND = 750V
DC
MI Chassis Overvoltage
and Transients
Compliant to Mil-STD 704 and 1399
[a]
Do Not to exceed an input current of 7.5A.
[b]
See Vicor module specifications. A preload may be necessary for modules trimmed down below 90% of normal
output voltage.