T186 Electronic Wall Sensor With Setpoint Adjustment

For Use With R842 Baseboard Relay

DESCRIPTION                                                                                                    

The T186 series remote wall sensor with setpoint adjustment capability is
specifically designed to be used with Viconics’ R842 electric baseboard relays.
The unique design of the R842 permits solid state proportional and integral (PI)
temperature control via the T186, resulting in exceptional temperature control
accuracy (± 0.5 ºF).
The T186 can replace conventional electro-mechanical thermostats when used
with the R842.  Advantages include increased comfort and energy savings.
Typical savings of 3-7% is possible and is attributed to the elimination of wasted
energy inherent in less accurate electromechanical thermostats.  Its solid state
design permits the elimination of bimetal elements and mercury bulbs, which
simplifies the installation since there is no anticipator and no levelling required.
In addition, it is an environmentally friendly product.
A pleasing aesthetic design ensures a harmonious blend in most room decors.
The T186 can be directly mounted to any flush vertical surface or to a standard
2” x 4” electrical mounting box via two mounting screws.  Celsius and Fahrenheit
models are available.
Using the T186 with the R842 relay will provide unmatched performance and
give years of trouble-free installation.

Fig.1 - T186 wall sensor with setpoint
adjustment

Fig.2 - R842 baseboard relay for electric
heaters

   Features

     Benefits

  Electronic PI performance

  Increased comfort , accuracy, and energy savings

  Solid state design

 Increased reliability

  No bimetal elements

  No need to worry about anticipator settings

  No mercury bulbs

  No levelling required; environmentally friendly

  Fahrenheit or Celsius temperature scale

  Can be sold world-wide

  Elegant aesthetic design

  Blends well in all environments

  Mounts on any surface or standard electrical box

 Increased flexibility

TABLE 1: ORDER CODE                                                                                                                                         

Scale Range

Sensor model

Replacement cover

5 °C to 30 °C

T186C-01

C186C-01

40 °F to 90 °F

T186F-01

C186F-01

WIRING DIAGRAM                                                               

APPLICATION & WIRING                                 

  Use proper dip switch setting on R842 relay

  Refer to each wiring caution

Viconics T186 PI Wall Sensor

Refer to Fig.3 for wiring diagram of T186 with
one R842 relay.

1  High voltage blue wire is always connected.  R842

units are powered devices.

2

Provide overload protection and disconnect as
required.

3

Do not use 24 Vac terminal #1 as power supply to an
electronic thermostat.  Use a separate transformer.

Fig.3 – Wiring diagram of T186 sensor with R842 relay

Note: refer to R842 manual for multiple relay application.

Junction box

Load side

RED

BLUE

Internal circuit

L1

L2 / N

T186

 sensor

2 wire non polarized

Set both switch on relay
to 

OFF

 position

1

2

ON

3

2

1

BLACK