Vicon VC2500-DSP Скачать руководство пользователя страница 1

COLORDIGITAL 

CAMERAS

 

 INDUSTRIES INC. 89 ARKAY DRIVE, HAUPPAUGE. NY 11788

 . 

 

 

 . 

   WORLD WIDE 

V

Содержание VC2500-DSP

Страница 1: ...NDVC26OOC DSP COLORDIGITAL CAMERAS I VICON INDUSTRIES INC 89 ARKAY DRIVE HAUPPAUGE NY 11788 TEL 516 95 CCTV 2288 fAX 518 951 CCTV 2288 TOLL FREE 800 645 9116 UK 44 0 1489 566300 lNFOFAX 800 287 1207 WORLD WIDE WEB www vicon cctvxom V 7c VICON ...

Страница 2: ...ire hazards do NOT use other than specified power source Warning This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio fre...

Страница 3: ...ning the camera body Use a dry cloth to clean the camera when dirtv In case the dirt is hard to remove use a mild detergent and wipe gently 5 Never point the camera toward the sun Whether the camera is used outdoors or not never point i toward the sun Use caution when operating the camera in the vicinity of spo lights or other bright I ights and I ight reflecting objects t t 6 Do not operate the c...

Страница 4: ...lPACKING LIST 1 Iris lens connector plug for DC drive lpc 2 C Mount lens adapter ring lpc 3 Dust protective cap lpc 3 ...

Страница 5: ...ICONNECTORS AND CONTROLS REAR PANEL TOP VIEW SIDE VIEW ...

Страница 6: ...d Power Supply Minimum 300 mA or 7 2 W Cautions 1 Connect to a class 2 power supply only 2 To prevent fire or shock hazard UL listed wire VW l style 1007 should be used for the cable Autoiris lens connector for video drive lens This connector supplies 9 VDC power and video signal without sync for video drive type autoiris lens PIN Signal 1 GROUND 2 POWER SUPPLY 9 VDC 40 mA 1 2 3 Back of camera 3 V...

Страница 7: ...ator LED E4 191 J 100 This LED turns ON only when power is supplied properly and the DC DC converter or the regulator inside the camera works wel I ALC level adjustment potentiometer for DC drive lens This potentiometer is used only if the camera is fitted with a DC drive autoiris lens It is used to control the amount of light striking the CCD image sensor LENS IRIS level LEVEL I Monitor screen LE...

Страница 8: ...nitor 3 Adjust the screen color to be white pushing AWB HOLD Push button I MODE SELECT SWITCH 1 LL INT sw tch This camera can operate independently using its internal crystal controlled sync generator or it may be synchronized using I ine locking To select one or the other of these sync modes set the DIP switch on the rear panel to either LL or INT If line locking is selected al I the cameras in t...

Страница 9: ...WITH BLC OFF 4 ELC ALC Select Switch WITH BLC ON This switch is used to select EE electronic exposure or ELC electronic light control mode or Al autoiris lens or ALC automatic I ight control mode In the EE mode a continuously variable electronic shutter is employed to automatically control the exposure time of the CCD image sensor according to the incoming light level With this mode selected a fix...

Страница 10: ...in EE mode with the manual iris lens fully opened may result in less depth of field and the distant objects in the picture may be seen out of focus 4 Fixed iris or manual iris lenses may be used with the linear shutter EE mode where the scene brightness varies over a limited range 5 Do not the EE mode when an autoir is lens is installed 5 ATW AWB Select Switch This c a m e r a has AUTO WHITE BALAN...

Страница 11: ...e making any adjustment confirm that cameras A and B are connected to the power supply with the same polarity To make an adjustment follow the steps below 1 While observing the video output signals from both cameras on an oscilloscope press camera A s V phase control push button on back of camera until vertical sync from both cameras are in phase 2 If camera A s adjustment range is insufficient ad...

Страница 12: ...ailable a less accurate adjustment can be made by observing the monitor and adjusting the V phase control push button until no roll occurs on the monitor when switching back and forth between cameras A and B A MONITOR AC ADAPTOR VIDEO I I SEQUENTIAL SWITCHER 11 ...

Страница 13: ... used the ad necessary To install the adapter first screw it into the opening on the camera Then screy the C mount I adapter II 3pter is not lens mount ens into the CAMERA LENS C MOUNT ADAPTER RING I CCD DUST PROTECTIVE CAP Remove this cap just before installing the lens Do not handle or leave the camera with this cap open CAMERA MOUNT HOLE 12 ...

Страница 14: ...and connect the camera to a monitor and power supply If the lens is motorized it must also be connected to a lens control Position the camera 25 50 feet 8 16 meters from a flat vertical surface suitable for focusing A newspaper works well as a focusing target Open the iris completely If an autoiris lens is used reduce the room I ighting to allow the lens to open completely This gives the most accu...

Страница 15: ...IEXAM XES OF CONNECTIONS 1 Simplest One monitor system with one camera AC ADAPTOR MONITOR CAMERA 14 ...

Страница 16: ...MPLES OF CONNECTIONS continued 2 One monitor system with two or more cameras CAMERA I AC ADAPTOR Y0 POWER L I t VIDEO L P lClLJ T l POWER VIDEO MONITOR 000000 RRRRRR O I SEQUENTIAL SWITCHER QUAD LITTER 15 ...

Страница 17: ...NE ADJUSTMENT WITH SELF LOCKING SYSTEM AUTO WHITE BALANCE 3 OOO K N 7 OOO K TTL CAMERA MOUNT FLUSH MOUNT TYPE TOP AND BOTTOM LENS MOUNT C or CS MOUNT C MOUNT ADAPTER RING INCLUDED AUTOIRIS SUPPORT VIDEO DRIVE TYPE WITH 3PIN TERMINAL DC DRIVE TYPE WITH 4PIN SQUARE CONNECTOR POWER REQUIREMENT 24 VAC 20 200mA MAX OPERATING CONDITION 14 F TO 122 F 10 C 5Ot WITHIN 85 RELATIVE HUMIDIT NET WEIGHT WITHOUT...

Страница 18: ...NTER WEIGHTED ZONE ELF LOCKING SYSTEM AUTO W I 10 K TTL CAMFRA w I MOUNT _ I FLUSH M INT TVPF h Ii I 1 I II L I 3P AND BOTTOM NS MOUNT A C or CS MOUNT UTOIRIS SUPPORT C MOUNT ADAPTER RING INCLUDED VIDEO DfIIVE TYPE WITH 3PIN TERMINAL nr nRI IC TVI vu v IIvL 1 iPE WITH 4PIN SQUARE CONNECTOR POWER REQUIREMENT 24 VAC 20 200mA MAX OPERATING CONDITION 14 F TO 122 F 1OoC 5O c WITHIN 85 RELATIVE HUMIDITY...

Страница 19: ...Off ice 3030 Business Park Drive Suite G Norcross Georgia 3OQ7 1 770 449 0499 l 800 824 8479 Fax 770 446 8779 European Headquarters Vicon Industries U K Ltd Brunel Way Fareham PO1 5 5TX United Kingdom 44 O 1489 566300 Fax 44 0 1489 566322 Vicon China Vicon Industries H K Ltd Unit 22 12 f Grandtech Centre 8 On Pirig Street Shatin New Territories Hong Kong 852 2145 7 118 fax 852 2145 7 117 Internet ...