This Quick Start Guide is intended for experienced installing
technicians. It is a basic reference to ensure all connections are
properly made. It is for models VAX-PCR-35L and VAX-PCR-640L.
For additional information please refer to Vicon's website
vicon-security.com.
1.0 Introduction
A key component of a physical security electronic access control
system, a mobile-ready reader combining BLE and proximity
technologies is based on RFID technology. In operation
it is capable of reading data stored on a proximity credential via radio
frequency—or reading data from mobile credential stored in a
smartphone’s wallet app via BLE technology—and without physical
contact, and then passing the data obtained to the physical access
control system. Access control systems typically manage
and record the movement of individuals through a protected area,
such as a locked door.
2.0 Mounting Provisions
Each reader may be installed either indoors or outdoors. Mounting
options shown in the table below. Use supplied #6 mounting screws,
or equivalent security screws, for installation.
Model
Mullion Mount
Single-Gang Wall Mount*
VAX-PCR-35L
•
•
VAX-PCR-640L
•
*Plastic or metal.
3.0 Reader Wiring
Wiegand
Magstripe
Conductor
Function
Conductor
Function
Red
DC (8-14 VDC)
Red
DC (8-14 VDC)
Black
Ground
Black
Ground
Green
Data 0
Green
Clock
White
Data 1
White
Data
Brown
Red LED
a
Brown
Red LED
Orange
Green LED
b
Orange
Green LED
Yellow
Not Used
Yellow
Not Used
Blue
Beeper
Blue
Beeper
Violet
Not Used
Violet
Not Used
Drain
Shield Ground
Drain
Shield Ground
4.0 Cable Requirements
24 AWG minimum, multi-conductor stranded with an overall foil shield,
for example Belden 9535 or similar, supporting the five conductors
comprising the physical layer of the Wiegand interface (power,
ground, data 0, data 1, and/or beeper and LED). Alternatively, Belden
9539 or similar, for all reader functions. Contact your access control
system manufacturer for their specific requirements. Per the SIA’s
Wiegand specification, maximum cable length is 500 feet (152 m).
5.0 Output Formats
• Wiegand (industry standard 26-bit Wiegand and custom
Wiegand formats)
• Magnetic Stripe (ABA Track II, clock and data, with card present)
6.0 Grounding
Shield (drain) continuity must run from the reader to the access
panel. Shield (drain) and reader ground must be tied together at
the access panel and connect to an earth ground at one point.
7.0 Power
Reader may be powered by the access panel. A linear power
supply is recommended for best operation.
8.0 Voltage and Current
Voltage: 8 to 14 VDC
Current Draw: 60mA typical, 90mA peak
9.0 Connection
Connection must be done in accordance with NFPA 70. Do
not connect to a receptacle controlled by a switch. Connect
to a power limited DC voltage source.
10.0 Troubleshooting
1. When the reader is first powered on it will beep 4-times,
and the LED will shine red.
2. Presenting a supported access credential will result in the
reader beeping and the LED flashing once.
3. Mobile operation is optimized for smartphones supporting
BLE (Bluetooth LE) version 4.2 or newer. Further, for
the downloading of mobile access credentials, a stable,
high-quality internet connection is recommended.
NOTE: The access panel controls LED functionality, such as
switching the LED to green.
XX274-85
WIRING NOTES:
a
Single Line LED:
This is the standard operating mode and does not make
use of the Orange conductor. The LED is Red when the reader is idle and
flashes when a card is presented. The LED turns Green when the Brown
Conductor is pulled low by the access control panel.
b
Dual Line LED:
This mode makes use of both the Brown and Orange
conductors. The Brown conductor controls the Red LED and the Orange
conductor controls the Green LED. LED states are determined by the
access control system option and capability.
Unused conductors should be trimmed, isolated and taped back to prevent
unintended current flows. Apply positive voltage only to the Red DC Conductor.
QUICK INSTALLATION GUIDE
VAX-PCR-35L AND VAX-PCR-640L