Part No. 8009-8056-15-00 Rev 602 

Instruction Manual XX056-15  

••

  1 

Instruction Manual XX056-15 
Introduction 

The information in this manual covers the installation of the V1411-EXP Expander Board for the V1411 Video 
Switcher. This unit should be installed by a qualified technician using approved materials in accordance with 
national, state and local codes. Read these instructions through completely before attempting installation. 
 
If the V1411 is to be expanded from 8 camera inputs and 2 monitor outputs to allow 16 camera inputs and four 
monitor outputs, a V1411-EXP must be installed. Refer to instruction manual XX056 for the V1411 for complete 
installation instructions. 

Installation 

Use the following procedure to install the V1411-EXP. 
 
1.  Be sure there is no power to the V1411 and unplug all connectors. 
2.  Remove the eight (8) M3 machine screws and washers that secure the cover, four (4) from the rear, two (2) from 

each side, and the two (2) countersunk M3 screws from the top and bottom. Remove the cover. Note that it 
might be necessary to slightly spring the ends of the enclosure to remove the cover. 

3.  Remove the faston receptacle connecting earth ground to the cover. 
4.  Remove the three (3) M3 pan head screws and washers that secure the L-shaped blank plate on the connector 

panel. The screws can be retained as spares for mounting the V1411-EXP; the blank plate is not needed and 
can be discarded. 

5.  Remove the red jumper fitted onto the middle set of pins on the 26-pin connector labeled PL3 on the edge of the 

main PCB in the V1411. 

6.  Position the V1411-EXP board onto the mounting lugs on the inside of the unit so that the connectors on the 

board go through the holes on the connector panel. Use the six (6) M3 pan head pozi screws and crinkle 
washers provided in the accessory kit to secure the V1411-EXP board. Lightly tighten the 2 corner screws and 
leave all the other screws loose. Make sure that the expander board is positioned correctly, so that the BNCs 
are centered correctly. Tighten all six (6) screws. 

7.  Connect the ribbon cable connector on the V1411-EXP board to PL3 on the V1411 main board, taking care to 

engage all pins onto the connector. 

8.  Replace the cover. Be sure that the earth ground receptacle is fully engaged with the faston tab on the inside of 

the cover. Secure the cover with the previously removed screws. Before tightening the screws, ensure that the 
ends of the enclosure are pressed fully inwards. 

9.  Plug the 9-pin terminal block provided in the accessory kit into the mating connector on the expander board that 

protrudes from the connector panel. Ensure that the dovetails in the plastic molding are properly engaged. Eight 
(8) 75 ohm terminators are provided for BNC connectors that are not used to loop out. 

10.  Replace the power cord and power up the unit. The yellow LED visible through the connector panel lights for 1 

second upon power up. If the unit is operating normally, the LED then flashes briefly (0.2 sec/1 sec) 
continuously. If there is an operating problem, the LED flashes for a more extended time (0.8 sec1 /sec); this 
indicates an internal failure that may result from the connection between the two PCBs being done improperly. 

 
 
Copyright © 2002 Vicon Industries Inc. All rights reserved. 
Vicon and its logo are registered trademarks of Vicon Industries Inc. 
Product specifications subject to change without notice. 
 
 

VICON INDUSTRIES INC., 89 ARKAY DRIVE, HAUPPAUGE, NEW YORK 11788 

TEL: 631-952-CCTV (2288)  FAX: 631-951-CCTV (2288)  TOLL FREE: 800-645-9116 

24-Hour Technical Support: 800-34-VICON (800-348-4266) 

UK: +44/(0) 1489-566300  INFOFAX: 800-287-1207  WEB: www.vicon-cctv.com

 

 