SVFT Daisy Chain Configuration
Model #: SVFT
Part #: XX045-70-00
Date: 6/14/04
Vicon Industries • www.vicon-cctv.com
Dual shielded
twisted-pair cable
(see table).
Max distance
5000 ft (1524 m )
end to end.
Dual shielded
twisted-pair cable
(see table).
Terminal Block
Part #: 8004-8089-08-00
Note: Main board (not shown)
switch SW2 pole 4 must
be set to ON for RS-485.
Note: Main board (not shown)
switch SW2 pole 4 must
be set to ON for RS-485.
Note: Main board (not shown)
switch SW2 pole 4 must
be set to ON for RS-485.
TB3
Cmd In+
Cmd In–
Gnd
2
3
1
4
5
Dual Shielded Twisted Pair
Cable Recommendations
Belden 9406
5000 ft (1500m)
Cable Type
Max Distance
Belden 9402
5000 ft (1500m)
Belden 8723
8000 ft (2400m)
Belden 8162
15000 ft (4600m)
Belden 9729
15000 ft (4600m)
Belden 9182
25000 ft (7600m)
Coaxial
TB
1
TB
2
TB
3
Terminal Block
Part #: 8004-8089-08-00
TB3
Cmd In+
Cmd In–
Gnd
2
3
1
4
5
TB
1
TB
2
TB
3
Terminal Block
Part #: 8004-8089-08-00
TB3
Cmd In+
Cmd In–
Gnd
2
3
1
4
5
TB
1
TB
2
TB
3
Resp Out+
Resp Out –
Resp Out+
Resp Out –
Resp Out+
Resp Out –
To Control Unit
Up to 32 SVFTs
in a Chain
Coaxial