Configuration
The Surveyor2000 must be configured for its address and mode and termination setting when using RS-485
protocol. The address and mode are set using the two 8-position DIP Switch banks S1 and S2. It is
necessary to determine which communication mode, Camera/Lens Module type and Surveyor2000 address
is required prior to configuration. Configuration should be performed just prior to final assembly and
installation. The termination setting is configured using 3 jumpers. This termination setting does not apply to
RS-422 mode.
Setting the DIP Switches
This section defines how to set DIP switches 1 and 2 (S1 and S2) on the Communications/Power Supply PC
switch 1
the appropriate video mode (PAL/OFF or NTSC/ON).
Board.
Figure 29
DIP Switch Location
Refer to Figure 29 for DIP switch location.
DIP switch 1 (S1) is used to set the
address as explained later. DIP switch 2
(S2) is used to set the mode functions.
Position 1 is the video mode setting,
NTSC (ON) or PAL (OFF). Position 2 is
the communication mode setting, Vicoax
mode (ON) or VPS/NOVA (OFF). Position
3 is the communication type setting,
SIMPLEX (ON) or HALF DUPLEX (OFF).
Position 4 is the protocol mode setting,
RS-485 (ON) or RS-422 (OFF). Each
switch is numbered from 1 to 8 and
marked to indicate the ON position.
Surveyor2000 will automatically detect the
system’s baud rate and will support 4800,
9600 and 19,200 kb/sec rates.
For RS-422/485 Mode:
1. Set switches 1 - 8 on DIP
(S1) to Surveyor2000’s address as
specified in Table 3. All addresses
between 0 and 255 are valid (address
0 is the same as camera number 256).
2. Set switch 1 on DIP switch 2 (S2) to
3. Set switch 2 on DIP switch 2 (S2) to the OFF position (VPS/NOVA mode).
4. Set switch 3 on DIP switch 2 (S2) to the appropriate communication mode (SIMPLEX or DUPLEX).
5. Set switch 4 on DIP switch 2 (S2) to the appropriate communication protocol (RS-422 or RS-485).
NOTE
: Switch 4 must be set to RS-485 protocol to enable daisy chain operation.
NOTE
: All Surveyor2000s in a daisy chain must have unique addresses for proper operation.
For Vicoax Mode:
1. Set switch 1 on DIP switch 2 (S2) to the appropriate video mode (PAL or NTSC).
2. Set switch 2 on DIP switch 2 (S2) to the ON position (
Vicoax
mode).
3. Set switches 3 and 4 on DIP switch 2 (S2) to either position, as it does not affect
Vicoax
protocol
operation.
NOTE
: DIP switches labeled ON or CLOSED and OFF or OPEN have the same meaning.
XX031-01 Rev 803 Surveyor2000 Camera Dome System
Configuration
•
39
Содержание SURVEYOR 2000 7003-00
Страница 2: ......
Страница 30: ...NOTES 26 Installation XX031 01 Rev 803 Surveyor2000 Camera Dome System...
Страница 46: ...NOTES 42 Configuration XX031 01 Rev 803 Surveyor2000 Camera Dome System...
Страница 48: ...NOTES 44 Uninstalling the Surveyor2000 XX031 01 Rev 803 Surveyor2000 Camera Dome System...
Страница 52: ...NOTES 48 Operation XX031 01 Rev 803 Surveyor2000 Camera Dome System...
Страница 56: ...NOTES 52 Shipping Instructions XX031 01 Rev 803 Surveyor2000 Camera Dome System...
Страница 63: ......