CIRCUIT POINTS AND OPERATION
-8-
Circuit points and operation
VIDEO
DC
ELC
ON OFF ON
FL AGC BLC
OFF ON OFF
DC LEVEL
AC24V/ DC12V FG
VIDEO OUT
VIDEO
DC
ELC
ON OFF ON
FL AGC BLC
OFF ON OFF
DC LEVEL
VIDEO OUT
230VAC
Rear view
12V DC / 24V AC Model
Rear view
230 V AC Model
Video, ELC, DC:
Change-over between video drive lenses
(Video), Auto Shutter (ELC) and DC
drive lenses (DC)
DC LEVEL:
Shutter adjustment during DC lense
operation
PL:
Power signal
FL:
Flickerless on / off
AGC:
Automatic gain on / off
BLC:
Back Light Control on / off
AC24V / DC 12V:
Power connection, the polarity with
12V DC makes no difference
FG:
Not connected
230V AC:
Mains voltage connecting lead
VIDEO OUT:
Video output to monitor etc.