instALLAtiOn And OPErAtiOn MAnuAL
CE-(X)COAX
TECH SUPPOrT: 800.34.VICON (800.348.4266)
iP CAMErA-End
instALLAtiOn (CE-1COAX
)
Set the remote/Local DIP switch to “remote”
mode.
Set the S1 DIP switch to the appropriate rate
based on the maximum data rate.
OFF = 10BaseT; ON = 100BaseT
Set the S2 switch to “On” for Master.
For systems not utilizing PoE, connect the 12
VDC or 24 VAC power supply to the power connector of the
CE-1COAX. A power adapter connector is provided to simplify
connection.
If there is no external power source connected, the
CE-1COAX will try to detect PoE.
Connect the IP camera rJ-45 connector to the 10/100BaseT
Ethernet port of the CE-1COAX using a standard Cat5/6 cable,
100 m length (max).
Connect one end of the long coax cable to the BNC connector
of the CE-1COAX.
EthErnEt switCh/nvr-End
instALLAtiOn (CE-(X)COAX)
S
et the remote/Local DIP switch to “Local”
mode.
Set the S1 10/100BaseT DIP switch to the
appropriate rate based on the maximum data
rate.
OFF = 10BaseT; ON = 100BaseT
Be sure the S2 switch to is set to “Off” for
Slave.
Note: The 4, 8 and 16 channel units are preset to Slave/Local
mode. No adjustment required.
Connect the 12 VDC or 24 VAC power supply to the power
connector of the selected CE-(X)COAX If there is no external
power source connected, the selected
CE-(X)COAX will try to detect PoE.
Connect the IP camera rJ-45 connector to the 10/100BaseT
Ethernet port of the selected CE-(X)COAX using a standard
Cat5/6 cable, 100m length (max).
Connect one end of the long coax cable to the BNC connector
of the selected CE-(X)COAX.
The Link LED on the 10/100 Ethernet connector should be
“ON” to indicate proper connection between the switch and
the selected CE-(X)COAX.
The Traffic LED on the Coax side should be “ON” and flashing
to indicate proper connection.
The Link LED (red for 100BaseT, Green for 10BaseT) will be “ON”
and not flashing to indicate confirmed connection between the
CE-COAX and selected CE-(X)COAX extenders.
S1 S2
S1 S2