Vicon part number 8009-8243-00-00   Rev 0112 

Page 5

instALLAtiOn And OPErAtiOn MAnuAL 

CE-(X)COAX

TECH SUPPOrT: 800.34.VICON (800.348.4266)

iP CAMErA-End  

instALLAtiOn (CE-1COAX

)

Set the remote/Local DIP switch to “remote” 

mode.

Set the S1 DIP switch to the appropriate rate 

based on the maximum data rate. 

 

OFF = 10BaseT; ON = 100BaseT

Set the S2 switch to “On” for Master.

For systems not utilizing PoE, connect the 12 

VDC or 24 VAC power supply to the power connector of the 

CE-1COAX. A power adapter connector is provided to simplify 

connection. 

If there is no external power source connected, the 

 

CE-1COAX will try to detect PoE.

Connect the IP camera rJ-45 connector to the 10/100BaseT 

Ethernet port of the CE-1COAX using a standard Cat5/6 cable, 

100 m length (max).

Connect one end of the long coax cable to the BNC connector 

of the CE-1COAX.

EthErnEt switCh/nvr-End 

instALLAtiOn (CE-(X)COAX)

S

et the remote/Local DIP switch to “Local” 

mode. 

Set the S1 10/100BaseT DIP switch to the 

appropriate rate based on the maximum data 

rate. 

 

OFF = 10BaseT; ON = 100BaseT 

Be sure the S2 switch to is set to “Off” for 

Slave. 

Note:  The 4, 8 and 16 channel units are preset to Slave/Local 

mode. No adjustment required.

Connect the 12 VDC or 24 VAC power supply to the power 

connector of the selected CE-(X)COAX If there is no external 

power source connected, the selected  

CE-(X)COAX will try to detect PoE.

Connect the IP camera rJ-45 connector to the 10/100BaseT 

Ethernet port of the selected CE-(X)COAX using a standard 

Cat5/6 cable, 100m length (max).

Connect one end of the long coax cable to the BNC connector 

of the selected CE-(X)COAX.

The Link LED on the 10/100 Ethernet connector should be 

“ON” to indicate proper connection between the switch and 

the selected CE-(X)COAX. 

The Traffic LED on the Coax side should be “ON” and flashing 

to indicate proper connection.

The Link LED (red for 100BaseT, Green for 10BaseT) will be “ON” 

and not flashing to indicate confirmed connection between the 

CE-COAX and selected CE-(X)COAX extenders.

S1  S2

S1  S2

Содержание CE-4COAX

Страница 1: ...er Coax extenders Environmentally hardened to the requirements of NEMA TS 1 TS 2 for most out of plant applications and true plug and play design ensures ease of installation and operation LED indicators are provided for rapidly ascertaining the operating status of the device See Figures 7 and 8 on page 6 for LED explanations Packaged in a rugged aluminum housing these units are designed for deskt...

Страница 2: ...no power supply connected to the unit it will try to detect PoE FIGURE 1 CE 1COAX FIGURE 3 CE 4COAX FIGURE 2 CE 1COAX INSTALLATION AND OPERATION MANUAL CE X COAX LEFT PANEL RIGHT PANEL LEFT PANEL 10BaseT 100BaseT 12 3 4 10BaseT 100BaseT 12 34 Note Center pin on power connector is positive Tech Support 800 34 VICON 800 348 4266 ...

Страница 3: ...pply Ground Screw 12V Power Supply Ground Screw FIGURE 4 CE 8COAX FIGURE 5 CLFE16COAX INSTALLATION AND OPERATION MANUAL CE X COAX Tech Support 800 34 VICON 800 348 4266 COAX 75Ω COAX 75Ω COAX 75Ω COAX 75Ω COAX 75Ω COAX 75Ω CAT5 6 CAT5 6 CAT5 6 CAT5 6 CAT5 6 CAT5 6 ...

Страница 4: ...E 16UTP PoE Switch 328 ft 100 m Cat 5 CE 4US1TPC IP Cameras IP Cameras Single Port Copper over Coax NVR PoE Switch 5 000 ft 1524 m Coax 328 ft 100 m Cat 5 CE 1COAX CE 1COAX PoE Camera Multi Port Copper over Coax NVR CE 16COAX PoE Switch 5 000 ft 1524 m Coax 328 ft 100 m Cat 5 CE 1COAX PoE Camera 3 000 ft 914 m Cat 5 5 000 ft 1524 m Coax Copper Managed High Power Midspan NVR CE 16IPS Switch Data Po...

Страница 5: ... DIP switch to Local mode Set the S1 10 100BaseT DIP switch to the appropriate rate based on the maximum data rate OFF 10BaseT ON 100BaseT Be sure the S2 switch to is set to Off for Slave Note The 4 8 and 16 channel units are preset to Slave Local mode No adjustment required Connect the 12 VDC or 24 VAC power supply to the power connector of the selected CE X COAX If there is no external power sou...

Страница 6: ...DICATORS FIGURE 8 RJ 45 LED INDICATORS POWER TRAFFIC Extended 10 100BaseT GREEN Connection is OK 10BaseT mode YELLOW RED Power is on Flashing Traffic present Connection is OK 100BaseT mode OFF Power is off No traffic RJ 45 TRAFFIC Standard Link GREEN Flashing Connection is OK with traffic YELLOW Connection is OK RED OFF No connection No connection ...

Страница 7: ... 95 mm 3 6 92 mm 17 432 mm 1 6 40 mm 3 3 84 mm 1 6 40 mm 1 75 44 5 mm 3 25 82 5 mm 1 6 40 mm 1 15 30 mm Tech Support 800 34 VICON 800 348 4266 Installation Considerations The CE 1COAX and CE 4COAX are supplied as standalone modules The CE 8COAX and CE 16COAX can be installed as standalone modules or can be rack mounted with the addition of the provided 19 inch rack mounting ear brackets MECHANICAL...

Страница 8: ...cluding DVRs that produce heat Protect the power cord from being walked on or pinched particularly at the power source convenience receptacles and the point where they exit from the apparatus Only use attachments accessories specified by the manufacturer Unplug this apparatus during lightning storms or when unused for long periods of time Refer all servicing to qualified service personnel Servicin...

Отзывы: