38
DMV-100 Rotor Creep and Speed Detector - Installation Manual
The relay switches as follows:
Table 3: Relay status according to event
Event Reported
Relay Status
Both LEDs inactive - main rack-mount unit powered-off
relay de-energized
Sensor and/or cable not connected
Red “ROTATION” LED active - rotation reported
Green “STOP” LED active - no rotation reported for more than 25 seconds
relay energized
5.3.5 Connecting 4-20 mA Output (RPM) Terminals
This 3-position connector delivers an analog RPM signal, which corresponds to the displayed reading.
Figure 35 : RPM output (4-20 mA) connector assignment
Note
:This output signal will drive a maximum resistive load of 500
.
To make use of this linear output, available to a controller or other third-party metering equipment,
apply the following transfer formula:
RPM = Linear Output (mA) X Max(RPM) – Min(RPM) + 5 Min(RPM) – Max(RPM)
16 4
4
where:
Min(RPM) = lower RPM limit as configured into the Speed Indicator
Max(RPM) = upper RPM limit as configured into the Speed Indicator
Linear Output (mA) =
reading at 4-20 mA output terminals
(see parameters
LSet.L
and
LSet.H
in Section
)