25
DMV-100 Rotor Creep and Speed Detector - Installation Manual
4.3 Connecting the cable to the DCC-631
The triaxial extension cable connects to the SMA socket and grounding screw. The standard M12 cable for
power input and signal output connects to the M12 socket.
1. Insert the SMA male connector and engage
by turning clockwise.
Recommended SMA connection
torque: 1.7 Nm
[15 lb-in
]
2. Insert the tooth lock washer, the round lug,
the spring lock washer and the nut onto the
grounding bolt. Screw the nut firmly to ensure
the grounding connection.
•
Recommended grounding connec-
tion torque: 2.8 Nm
[25 lb-in
]
•
The ground lug must not come in
contact with neither SMA con-
nector nor M12 connector.
Figure 25 : Cables connected to the DCC-631 module
Table 1: DCC-631 module M12 connector configuration
Position
Wire color
Designation
1
Brown
+24 V
DC
supply
2
White
(future use)
3
Blue
Common
4
Black
Creep detection signal
5
Gray
Pulse (1/pole)
Shield
(ends at M12 connector plastic body
Содержание DMV-100
Страница 1: ...DMV 100 Rotor Creep and Speed Detector Installation Manual...
Страница 6: ...6 DMV 100 Rotor Creep and Speed Detector Installation Manual...
Страница 10: ...10 DMV 100 Rotor Creep and Speed Detector Installation Manual...
Страница 50: ...50 DMV 100 Rotor Creep and Speed Detector Installation Manual...