How To ...
54
© 1995-2005 Vibration Research Corporation. All rights reserved.
VVIEW_E_RECORDING
(0x0211)
Could not start requested test as the recorder is active and starting the test would interrupt the
recording session
VVIEW_E_FAILEDTOSAVE (0x0212)
Tried to save the data file, but save failed. Check for read-only attribute on the requested save file and
sufficient disk space.
VVIEW_S_WAITING_FOR_BOX (0x0213)
Waiting for IOBox to initialize, data returned will remain zero until the box is initialized.
VVIEW_E_WINDOWSERROR(0x214)
Windows returned an error, check the error message on the dialog itself.
See Also:
Excel
example spreadsheet on distribution CDROM \Examples\ActiveX
2.7.4
How to use a file to control VibrationVIEW
How to use an ASCII file to control VibrationVIEW
Remote control requires the optional ActiveX component of
VibrationVIEW
.
To control
VibrationVIEW
with an ASCII file:
1.
Edit the "C:\Program Files\VibrationVIEW4\shaker.ini" file
2.
Locate the "[System Parameters]" section in the file.
3.
Add this line: "Remote Control File=C:\Program Files\VibrationVIEW4\RemoteControl.txt".
4.
Start
VibrationVIEW
.
VibrationVIEW
will now monitor the file "C:\Program Files\VibrationVIEW4\RemoteControl.txt".
VibrationVIEW
will report status in a new file "C:\Program
Files\
VibrationVIEW
4\RemoteControl.Status". To remotely control
VibrationVIEW
you can write the
following commands to this RemoteControl.txt.
load <FileName>
This command will load test profile specified with fully qualified path
<FileName>
run
Run the currently loaded test
mat <FileName>
Save the data to file <FileName> as a
Matlab
file
csv <FileName>
Save the data to file <FileName> as a comma delimited file
save <FileName>
Save the data to file <FileName> as a
VibrationVIEW
file
stop
Stop the currently running test.
status
Write the current StopCode to RemoteControl.Status
See Also:
Visual Basic (version 5) example code on distribution CDROM \Examples\VBTest
2.8
How to create customized reports
2.8.1
Overview
How to create customized reports
Reports are generated using mail merge type processing. The program reads in a template file,
substitutes data values and graphs in place of keywords, and writes the resulting data to an output file.
The template files can be either plain text or Rich Text Format files. Plain text files can have data
values but no graphs. Rich Text Format files (using extension .rtf) can contain data values and graphs,
Содержание VibrationVIEW
Страница 15: ...Document Revision Part I ...
Страница 17: ...How To Part II ...
Страница 96: ...Menu commands Part III ...
Страница 142: ...Test Definition Part IV ...
Страница 217: ...Control Centers Part V ...
Страница 226: ...VibrationVIEW Help 213 1995 2005 Vibration Research Corporation All rights reserved See Also RecorderVIEW 309 ...
Страница 227: ...Accelerometer Toolbars Part VI ...
Страница 231: ...Stop Codes Part VII ...
Страница 263: ...Typical Views Part VIII ...
Страница 265: ...Typical Views 252 1995 2005 Vibration Research Corporation All rights reserved 8 4 Random Random CRT View ...
Страница 268: ...VibrationVIEW Help 255 1995 2005 Vibration Research Corporation All rights reserved ...
Страница 269: ...Dialog Boxes Part IX ...
Страница 303: ...Windows Elements Part X ...
Страница 309: ...APPENDIX Part XI ...
Страница 311: ...APPENDIX 298 1995 2005 Vibration Research Corporation All rights reserved ...