Dialog Boxes
260
© 1995-2005 Vibration Research Corporation. All rights reserved.
Delete Graph allows removal of previously inserted graphs.
Special graph type "Text Window" can be used to add additional space for text above or below the
graphs. To make a version 4 type "Text at Bottom" press the "Insert Graph" button to add another
graph to the bottom, then set the newly inserted graph type to "Text Window".
Tip: The 'Graph Legends' fields can also include report parameter fields so you can include specific
test values in these fields. For example, you can use the setting "Started at [PARAM:StartTime]" to
insert the time the test was started. See '
' for a full list of parameter
fields that can be used here.
9.3.2
COLA Slip Frequency dialog box
COLA Slip Frequency dialog box
In Sine test mode selecting the
menu command displays this dialog box.
Use this dialog box to adjust the frequency or phase shift for the Constant Output Level Adapter
(COLA) output. This is useful for triggering stroboscopes at a frequency/phase slightly shifted from the
excitation frequency/phase so that the stroboscope may be used to see device vibration in slow
motion.
In Frequency mode, shifts between -5 Hz and +5 Hz may be selected by dragging the slider, or by
typing a value in the offset box. If a number is typed in the box, you must click the Set button to
activate the new setting.
In Phase mode, shifts between -360 degrees and +360 degrees may be selected by dragging the
slider, or by typing a value in the offset box. If a number is typed in the box, you must click the Set
button to activate the new setting.
In both modes, a multiplier may be set by using the drop down box, or by typing a value in the Multiplier
box. If a number is typed in the box, you must click the Set button to activate the new setting.
Note: The multiplier must be a whole number when the Offset units is set to Degrees. If an integer is
entered, the software will round that number to the nearest whole number.
9.3.3
Edit Frequency dialog box
Edit Frequency dialog box
In Sine test mode, clicking the "Frequency" button in the
displays this dialog
box.
65
125
206
Содержание VibrationVIEW
Страница 15: ...Document Revision Part I ...
Страница 17: ...How To Part II ...
Страница 96: ...Menu commands Part III ...
Страница 142: ...Test Definition Part IV ...
Страница 217: ...Control Centers Part V ...
Страница 226: ...VibrationVIEW Help 213 1995 2005 Vibration Research Corporation All rights reserved See Also RecorderVIEW 309 ...
Страница 227: ...Accelerometer Toolbars Part VI ...
Страница 231: ...Stop Codes Part VII ...
Страница 263: ...Typical Views Part VIII ...
Страница 265: ...Typical Views 252 1995 2005 Vibration Research Corporation All rights reserved 8 4 Random Random CRT View ...
Страница 268: ...VibrationVIEW Help 255 1995 2005 Vibration Research Corporation All rights reserved ...
Страница 269: ...Dialog Boxes Part IX ...
Страница 303: ...Windows Elements Part X ...
Страница 309: ...APPENDIX Part XI ...
Страница 311: ...APPENDIX 298 1995 2005 Vibration Research Corporation All rights reserved ...