※ For AJH series (With-internal-calibration type),
refer to section 5-6
(5) Remove three mechanism unit fixing screws
(6) Remove the mechanism unit by holding at the chassis.
Mechanism Unit Fixing Screws
5-3-1-2 AJ-2200〜12K
(1) Remove the case referring to 5-1
(2) Remove Wires to the Tuning-fork sensor, by welding solders
at AJDP circuit board.
(3)Remove the AJDP circuit board fixing screw and AJDP circuit board.
Soldered
AJDP Circuit Board Fixing Screws