Appendix A
Specifications
MSAM specifications
T-BERD/MTS/SC Getting Started Guide
March 2018
22046537, Rev. 016
Page 203
lists the input sensitivity specifications for the E1 receiver.
Transmitter (RJ-48)
The E1 transmitter operates as per ITU-G.703 (11/01).
lists the transmitter
specifications.
Frequency measurement
Range: 2.048 MHz ±250 ppm
Accuracy: ±1.5 ppm, ±1 ppm per year aging
Resolution: 1 Hz
Level Measurement
(Balanced)
Level Vp
Range: +4 V to 0.03 V
Accuracy: ±0.02 V ± 10%
Resolution: 0.01 V
Level dBnom
1
:
Range: +2.5 dBnom to -37 dBnom
Resolution: 0.1 dB
1. The designation in dBnom is relative to nominal signal 3 Vp.
Table 94
E1 RJ-48 receiver sensitivity specifications
Termination Type
Impedance
Input Range
Bridge (HI-Z)
>1200
Ω
+2.5 to -35 dBnom due to cable loss
Terminate
120
Ω
balanced
+2.5 to -35 dBnom due to cable loss
PMP
120
Ω
balanced
-20 dBnom due to resistive loss in
addition to 0 to -6 dB due to cable loss
Table 93
E1 RJ-48 receiver specifications (Continued)
Parameter
Specification
Table 95
E1 RJ-48 transmitter specifications
Parameter
Specification
Connector
Balanced RJ-48
Line code
HDB3 or AMI
Bit rate
Nominal: 2.048 Mbps
Accuracy: ±1.5 ppm, ±1 ppm per year aging
Frequency offset: ±100 ppm in 1 ppm steps
Clock Source
(Timing)
– Internal reference clock with accuracy ±1.5 ppm,
±1 ppm per year aging
– Recovered from Rx1
– External from BITS, SETS, or CLOCK
Frequency offset
±100 ppm in 1 ppm steps
Pulse shape
Complies with ITU-T G.703 (11/01)