VIAVI Solutions
5.
Navigate to
All Streams
settings.
6.
Configure appropriate
Source IP
,
Subnet
Mask
and
Default Gateway
parameters for
the TBERD 5800 test port, leave all other
parameters at defaults.
Figure 8: All Stream settings
7.
Navigate to
TCP Host
settings.
8.
If the circuit under test uses VLAN tagging,
select
Ethernet
tab, set the
Encapsulation
parameter to
VLAN,
and configure the
appropriate VLAN ID and Priority values.
Figure 9: TCP Host, Ethernet Settings
9.
Select
TCP Host Settings
tab.
10.
Set the
iPerf Version
parameter to
3
.
11.
Set the
Direction
parameter to
Upstream
to test in the TBERD 5800 to iPerf server
direction or to
Downstream
to test in the
iPerf server to TBERD 5800 direction.
12.
Set the
Connect to Server
parameter to
the IP address of the iPerf server.
13.
Set the
Connect to Port
parameter to TCP
port the iPerf server is listening on.
14.
Set the
Window Size
parameter to
4194304 bytes.
15.
If required adjust the
Max Seg Size
parameter to match the circuit under test
configuration, otherwise leave at default.
16.
If required configure the
TOS
or
DSCP
values to match the circuit under test
configuration, otherwise leave at defaults.
17.
Set the
Transmit Mode
parameter to
Time
and set the
Time
parameter to desired test
duration in seconds.
18.
Set the
Number of Connections
parameter
to desired value.
19.
The T-BERD 5800 is configured for the test.
Figure 10: TCP Host Settings