5.

 

Navigate to 

All Streams

 settings.   

 

6.

 

Configure appropriate 

Source IP

Subnet 

Mask

 and 

Default Gateway

 parameters for 

the TBERD 5800 test port, leave all other 
parameters at defaults. 

 

Figure 8: All Stream settings 

 

7.

 

Navigate to 

TCP Host

 settings. 

 
8.

 

If the circuit under test uses VLAN tagging, 
select 

Ethernet

 tab, set the 

Encapsulation

 

parameter to 

VLAN,

 and configure the 

appropriate VLAN ID and Priority values. 

 
 

 

Figure 9: TCP Host, Ethernet Settings

 

9.

 

Select 

TCP Host Settings

 tab. 

10.

 

Set the 

iPerf Version

 parameter to 

3

11.

 

Set the 

Direction

 parameter to 

Upstream

 

to test in the TBERD 5800 to iPerf server 
direction or to 

Downstream

 to test in the 

iPerf server to TBERD 5800 direction. 

12.

 

Set the 

Connect to Server

 parameter to 

the IP address of the iPerf server. 

13.

 

Set the 

Connect to Port

 parameter to TCP 

port the iPerf server is listening on. 

14.

 

Set the 

Window Size

 parameter to 

4194304 bytes. 

15.

 

If required adjust the 

Max Seg Size

 

parameter to match the circuit under test 
configuration, otherwise leave at default. 

16.

 

If required configure the 

TOS

 or 

DSCP

 

values to match the circuit under test 
configuration, otherwise leave at defaults. 

17.

 

Set the 

Transmit Mode

 parameter to 

Time

 

and set the 

Time

 parameter to desired test 

duration in seconds. 

18.

 

Set the 

Number of Connections

 parameter 

to desired value. 

19.

 

The T-BERD 5800 is configured for the test. 

 

Figure 10: TCP Host Settings

 

Содержание T-BERD/MTS-5800

Страница 1: ...match the line under test Patch Cables to match the optical transceiver and line under test CAT5E Single mode or Multimode Fiber Fiber optic inspection microscope VIAVI P5000i or FiberChek Probe Fiber Optic Cleaning supplies Figure 1 Equipment Requirements The following information is required to complete the test Physical Interface 10 100 1000BASE T 1000BASE SX 1000BASE LX 10GBASE LR etc Auto Neg...

Страница 2: ...le with the interface under test Launch and Configure Test 1 Press the Power button to turn on the test set and view the startup screen 2 Using the Select Test menu Quick Launch menu or Job Manager launch an Ethernet Layer 4 TCP Wirespeed IPv4 Terminate test on port 1 for the desire physical interface For example Ethernet 10 100 1000 Layer 4 TCP WIrespeed IPv4 P1 Terminate 3 If the test is not in ...

Страница 3: ... 5800 to iPerf server direction or to Downstream to test in the iPerf server to TBERD 5800 direction 12 Set the Connect to Server parameter to the IP address of the iPerf server 13 Set the Connect to Port parameter to TCP port the iPerf server is listening on 14 Set the Window Size parameter to 4194304 bytes 15 If required adjust the Max Seg Size parameter to match the circuit under test configura...

Страница 4: ...w and be relabeled 3 Ensure the TBERD 5800 test port established a link to circuit under test as indicated by green Signal Present optical test port only Sync Acquired and Link Active LEDs 4 Set the real time test results view to TCP Host Detailed L4 Stats 5 To start the TCP Throughput test tap on the Start TCP Client button on the Actions tab at the bottom of the screen and observe the real time ...

Отзывы: