1.

If files are to be saved, tap the 

File

soft key 

and tap the fiber folder                .   
Otherwise proceed to step 4.

2.

Tap the 

Create Directory

soft key, 

enter a name for your new folder and tap the 

Enter

key.  All trace files will be saved to this 

directory.

3.

Tap the 

Exit

soft key      .

4.

Tap the 

Setup

soft key      to display the Setup 

menu.

5.

Tap 

Auto-set

to auto-configure the OCC for a 

single sweep. 

6.

Tap the 

Analysis

tab. If a splitter/tap is used to 

access the signal, set 

Splitter Value 

to the 

splitter loss (in dB or %).

LAUNCH  TEST

1.

Press the Power button   
to start the test instrument.

2.

Tap the 

Fiber Optics 

icon   

in the Status Bar at the top of the screen.

3.

If a purple      symbol is displayed on the left 
screen side, tap it to display the 

Fiber Optics 

home screen. 

4.

Tap the 

COSA 

icon        until it is yellow and 

highlighted. 

Figure 5: Fiber Optics Home Screen

Figure 7: Setup Menu

CONFI GURE  TEST

Figure 6: File Menu

Содержание T-BERD/MTS-580

Страница 1: ...t Requirements CWDM Optical Channel Checker This quick card describes how to connect to a fiber under test configure CWDM Optical Channel Checker OCC test setups run tests and analyze results with a T BERD MTS 5800 equipped with a COSA 4055 module Note The COSA module is used to monitor wavelengths on a live network Care should be exercised when unplugging fibers from the network as the fibers may...

Страница 2: ... via a coupler during turn up or maintenance Figure 3 Connecting to Monitor Port Figure 4 Connecting to Common Cable 1 Inspect the OCC port on top of the test set 2 If connecting to the Common Cable connect the Common Cable to an optical coupler with the same connector type and inspect the fiber end face in the coupler 3 If connecting to the Monitor Port or Common Port on the Mux inspect the Mux P...

Страница 3: ...to display the Setup menu 5 Tap Auto set to auto configure the OCC for a single sweep 6 Tap the Analysis tab If a splitter tap is used to access the signal set Splitter Value to the splitter loss in dB or LAUNCH TEST 1 Press the Power button to start the test instrument 2 Tap the Fiber Optics icon in the Status Bar at the top of the screen 3 If a purple symbol is displayed on the left screen side ...

Страница 4: ...wn in Figure 8 Test Results 3 Verify that traffic is on all expected channels at the anticipated wavelengths and power levels and that there are no unexpected wavelengths present 4 Things to look for Every expected wavelength channel is present Channels are about 20 nm apart Power levels of each channel are within roughly 3 dB of each other or within the relative amplitude specification of the Net...

Отзывы: