Run Test:
1.
Press the
RESULTS
button.
2.
Press the
START/STOP
button to start the test. After auto-configuration, the OTDR will perform
a connection check to ensure that the connection is
Good
. If the Connection is
Bad
, repeat steps 1 through 7
on page 2.
3.
The OTDR will perform acquisitions at two wavelengths and the trace file will be saved to disk. Results may
be displayed in 3 different formats: Trace view, SmartLink Summary View, or SmartLink Event View.
Tap the
Trace/SmartLink
soft key
, to toggle between
Trace view
and
SmartLink views
.
Tap the
soft key to toggle between the
SmartLink Summary
view and
SmartLink Event View
:
a.
Trace view
: Results for each wavelength are shown in different
colors in the top section of the display. Each event is listed in
the lower section of the display. Any events that violate
pass/fail thresholds for loss or reflectance are shown in
RED
.
Use the right and left arrow button to Toggle between results
for each wavelength. Tap the
Zoom
soft key
, to enable
zoom controls with the following buttons:
•
Toggle between automatic zoom and full trace view
•
Expand and contract trace.
b.
SmartLink Summary view:
The FUT is displayed as a series of
icons representing events (connectors, splices, bends, etc.). The
center of the display shows summary results per wavelength for
the entire span. Acquisitions for which all events are acceptable
are marked with a green check
. Acquisitions with events
that exceed pass/fail thresholds for loss or reflectance are
marked with a red
. The lower display shows each event that
exceeds thresholds.
c.
SmartLink Event view:
The FUT is displayed as a series of labels
icons representing each event in the trace:
•
BBU:
Connection (coupler) between launch cable and BBU
Jumper Cable
•
BOT TWR
: Optical Patch Panel at bottom of tower
•
TOP TWR
: Junction Box/Patch Panel at Top of tower
•
RRU
: End of RRU Jumper Cable
Any events that violate pass/fail thresholds for loss or
reflectance are shown in
RED
. Tap on any event to display
details in the lower display.
Figure 3: Trace view
Figure 4: SmartLink Summary View
Figure 5: SmartLink Event View
4.
Repeat steps 2 and 3 for all Fibers under test.