OLS-34V2/-35V2/-36V2/-38V2
19
E
NABLING
SIGNAL
MODULATION
4 O
PERATION
Enabling signal modulation
Modulation frequencies provided by the OLS-3xV2:
CW (continuous wave), 270 Hz, 330 Hz, 1 kHz, 2 kHz
NOTE:
Signal modulation is available in Single-
(all models) and
Singlemode (OLS-36) only.
To select a modulation frequency:
I
Single-
is selected.
J
Press [
] to skip through the list: CW
270 Hz
330 Hz
1000 Hz
2000 Hz
CW
...
Selecting Auto-Lambda mode
Auto-
is a special feature developed by Viavi that allows you to
identify wavelengths automatically. To do this, the signal is
modulated at a certain frequency, which can be detected by an
Auto-
equipped power meter (such as the Viavi OLP-3x series).
To activate Auto-
:
J
Press
[MODE]
to skip through the modes and select Auto-
.
The status bar shows Auto-
.
NOTE:
Signal modulation cannot be selected when Auto-
is enabled.
Selecting Multi-Lambda mode
When Multi-
mode is activated, the signal of the available
wavelengths are sent in parallel.
Fig. 2
Example of Multi-
at OLS-36 with SM selected.
To activate Multi-
:
J
Press
[MODE]
to skip through the modes and select Multi-
.
The display shows Multi-
.
NOTE:
Signal modulation cannot be selected when Multi-
is enabled.