Seeker X User’s Guide
22137808, Rev. 001
Feb 2020
58
Chapter
4 Appendix
Specifications
Seeker X
Frequency Range
130–150 and 250–1220 MHz, adjustable via Seeker Setup Software
and Mobile Tech App
Frequency Settings
4 user selectable frequency presets, plus 4 different selectable
frequency plans.
Receiver Sensitivity
-158 dBm
Calibrated Level Range
1–2000 µV/m
Level Accuracy
±2.0 dB
Display
Dual numerical readout of up to 2 detected leakage frequencies and
carrier types within sensitivity range
Audible Tone
Tone is present if leakage amplitude exceeds squelch setting and
digital tag is detected
Pitch is proportional to strength of leak
Automatic Noise and
Overbuild Discrimination
Internal circuitry discriminates between leaks and noise
Overbuild discrimination provided by CT-X channel tagger installed in
hub or head-end
Power
Internal battery with 3 hours of operation per charge; ~2 hours
charging time
OR
Vehicle power of 12 VDC while in Mobile Mount
Configuration Methods
y
StrataSync with the Mobile Tech App via Bluetooth Low-Energy
Connection
y
USB connection from Leakage Detector to local PC running Seeker
Setup Software
Seeker MCA III (Optional)
Standard Communications
Interfaces
10/100 RJ45 connection to fleet management systems
WiFi (802.11 a/b/g/n) to operator-controlled and configured hot-spot
Early Detection Notification (EDN)
Email notification of threshold exceeding leaks
Содержание Seeker X
Страница 1: ...Seeker X Digital Leakage Detection System User s Guide ...
Страница 6: ...Seeker X User s Guide 22137808 Rev 001 Feb 2020 6 ...
Страница 10: ...Seeker X User s Guide 22137808 Rev 001 Feb 2020 10 Contents ...
Страница 18: ...Seeker X User s Guide 22137808 Rev 001 Feb 2020 18 About this Guide ...
Страница 32: ...Seeker X User s Guide 22137808 Rev 001 Feb 2020 32 Chapter 1 Quick Tour ...
Страница 52: ...Seeker X User s Guide 22137808 Rev 001 Feb 2020 52 Chapter 2 Using Your Seeker X ...
Страница 56: ...Seeker X User s Guide 22137808 Rev 001 Feb 2020 56 Chapter 3 Leakage Testing ...