ONX-220 User's Guide
22135173, Rev. 000
June 2020
90
Chapter
4 CATV Testing
To run Cable Fault Finder
1. Select
Cable Fault Finder
under the CATV menu header. The Cable Fault Finder
Setup screen appears.
2. Select the mode:
Drop Check
or
Cable Length.
3. For Drop Check, select the desired demarcation point to be tested:
Tap
or
Ground Block
. A graphic showing the appropriate connection schematic for this
test will appear along with appropriate instructions for the port to be used.
4. Assign this test to a saved work order (optional but recommended).
Select the
Work Order ID
button and the list of available work orders will
appear. Select one.
5. Configure the cable type or create a new one.
6. Start the test by selecting the
Start
button at the bottom of the screen.
Results
For a detailed discussion of the results produced by this test, see
.
Cable Length
Similarly, the Cable Length mode is intended to measure any coax cable’s length, looking
for a single reflection. This is helpful if you need to order a replacement drop and need
to determine the length and verify after the replacement is complete.
Содержание ONX-220
Страница 1: ...ONX 220 User s Guide ...
Страница 8: ...ONX 220 User s Guide 22135173 Rev 000 June 2020 8 ...
Страница 34: ...ONX 220 User s Guide 22135173 Rev 000 June 2020 34 Chapter 1 Quick Tour ...
Страница 78: ...ONX 220 User s Guide 22135173 Rev 000 June 2020 78 Chapter 3 Menus and Workflow ...
Страница 98: ...ONX 220 User s Guide 22135173 Rev 000 June 2020 98 Chapter 5 Ethernet Testing ...
Страница 170: ...ONX 220 User s Guide 22135173 Rev 000 June 2020 170 Chapter 10 Using the OneExpert with a Mobile Device ...
Страница 198: ...ONX 220 User s Guide 22135173 Rev 000 June 2020 198 Chapter 11 Test Results ...
Страница 211: ......