FA S T  R E P O RT

1.

Tap the 

File

soft key        and tap the 

Project 

folder.  

2.

Tap the 

Create Directory 

soft key         and 

enter a name for your new folder.  All trace files 
will be saved to this directory.

3.

Tap the 

Exit

soft key        . 

4.

Tap the 

Fast Report 

soft key        and enter 

Cable ID

Fiber Number

Locations

Direction

, and 

Save Mode

.

5.

Tap 

Save

.

6.

Tap         to accept the default filename and 
save test results.

7.

Tap the 

Fast Report 

soft key again to return to 

the results display.

Figure 15: File Explorer

Figure 16: Fast Report

Содержание OneAdvisor-1000

Страница 1: ...run inspection test Repeat until it passes Figure 2 Inspect Before You Connect Figure 1 Equipment Requirements 4100 series Expert OTDR This quick card explains how to connect to a fiber under test configure EXPERT OTDR test settings using Quick Setup run tests and analyze results on a VIAVI ONA 1000 equipped with a 4100 series OTDR module ONA 1000 equipped with the following Fiber Optics Software ...

Страница 2: ...of the Launch Cable 3 Connect the Launch Cable to the OTDR port 4 If the interface to the FUT is a patch cord connect the patch cord to an optical coupler 5 Inspect the FUT connected to the coupler or OPP port and the fiber end face of the Launch Cable 6 Connect the Launch Cable to the coupler or OPP port Figure 5 Connecting to OPP LAUNCH TEST 1 Press the Power button on the top of the OneAdvisor ...

Страница 3: ...lect Auto to automatically configure Range Pulse width and Resolution settings Select SmartAcq to perform an acquisition with a short pulse width followed by an acquisition with a longer pulse width The first acquisition allows events at the beginning of the fiber to be detected more precisely Acq Time Select Realtime Auto or the desired time to sample the fiber Launch Cable Select and enter Lengt...

Страница 4: ...b at the left screen top to select SmartLink view 2 Set the toggle switch at the right screen top to Event Line 3 View SmartLink results The FUT is displayed as a series of icons representing events front connector launch cable connectors splices bends etc and distances Swipe left or right to view additional icons on spans with more than 4 events The center of the display shows summary results for...

Страница 5: ...he upper display Graphical results dB versus distance are shown in the center display A color coded Event table is shown in the lower display Swipe up and down to view all events Figure 13 Trace view Figure 14 Table view 1 Tap the Table tab at the left screen top to select Table view 2 Set the toggle switch at the right screen top to the center off position 3 View table results Distance Loss and R...

Страница 6: ...utions com contact 1 844 GO VIAVI 1 844 468 4284 FAST REPORT 1 Tap the File soft key and tap the Project folder 2 Tap the Create Directory soft key and enter a name for your new folder All trace files will be saved to this directory 3 Tap the Exit soft key 4 Tap the Fast Report soft key and enter Cable ID Fiber Number Locations Direction and Save Mode 5 Tap Save 6 Tap to accept the default filenam...

Отзывы: