VIAVI//Public
OneAdvisor-1000 Portable Network Tester
OneAdvisor-1000 Portable Network Tester
Q U I C K C A R D
3
C O N F I G U R E T E S T
Figure 7: Setup, Display
1.
Tap the
Setup
soft key
.
2.
Tap
Display
and set
Distance Unit
to your
desired unit of measure.
3.
Tap
Acquisition
and configure the following
basic settings for the trace:
►
Laser:
Select the wavelength(s) to test.
–
Select
All
or select
1310 nm
and
1550 nm
to enable bend detection.
►
Acquisition Mode
:
–
Select
Manual
to manually to enter
Range and Pulse width settings.
–
Select
Auto
to automatically configure
Range, Pulse width, and Resolution
settings.
–
Select
SmartAcq
to perform an
acquisition with a short pulse width,
followed by an acquisition with a longer
pulse width. The first acquisition allows
events at the beginning of the fiber to
be detected more precisely.
►
Acq. Time
: Select Realtime, Auto or the
desired time to sample the fiber.
►
Launch Cable
: Select and enter
Length
if you are using a Launch Cable.
Enter 20 meters or 66 feet for Viavi
supplied 20-meter launch cables.
4.
Tap
Alarms
and configure pass/fail criteria:
►
Set
Alarm Level
to
Fail.
►
Set
Threshold
to
Default
, or select
alternate alarm thresholds (TIA-568.3,
User, etc.)
Figure 8: Setup, Acquisition
Figure 9: Setup, Alarms