Ethernet Y.1564 Layer 2 Traffic

This quick card describes how to configure and run a Y.1564 Layer 2 Traffic Test for Metro 
Ethernet service activation. 

Figure 1: Equipment Requirements

L A U N C H  T E S T

1.

Press the Power button       to turn on the 
OneAdvisor.

2.

Press the 

400G Module

icon                  at the 

screen top to display the 

Launch Screen

.

3.

Using the 

Select Test 

menu, Quick Launch 

menu, or Job Manager, launch the Ethernet 
Y.1564 SAMComplete Multiple Streams test on 
Port 1 for the desired rate.  For Example:  

Ethernet 

1GigE Optical 

Y.1564 SAMComplete 

L2 Traffic 

P1 Terminate.

4.

Tap the                   button next to “

Start a New 

Configuration (reset to defaults)

” 

Figure 2: Launch Screen

Figure 3: Y.1564 SAMComplete test

OneAdvisor 1000 400G Module equipped with the following:

o

Transport software release V3.1.0 or greater

o

CA10M1GE test option for 10 Megabit to 1 Gigabit Ethernet

o

CA10GELAN test option for 10 Gigabit Ethernet

o

CA25GE  test option for 25 Gigabit Ethernet

o

CA40GE test option for 40 Gigabit Ethernet

o

CA50GE test option for 50 Gigabit Ethernet

o

CA100GE  test option for 100 Gigabit Ethernet

o

CA200GE  test option for 200 Gigabit Ethernet

o

CA400GE test option for 400 Gigabit Ethernet

Optical Transceiver supporting the line rate to be tested (SFP or QSFP)

Cables to match the optical transceiver and the line under test

Fiber optic inspection microscope (P5000i or FiberChek Probe)

Fiber optic cleaning supplies

Содержание OneAdvisor 1000

Страница 1: ...ffic P1 Terminate 4 Tap the button next to Start a New Configuration reset to defaults Figure 2 Launch Screen Figure 3 Y 1564 SAMComplete test OneAdvisor 1000 400G Module equipped with the following o Transport software release V3 1 0 or greater o CA10M1GE test option for 10 Megabit to 1 Gigabit Ethernet o CA10GELAN test option for 10 Gigabit Ethernet o CA25GE test option for 25 Gigabit Ethernet o...

Страница 2: ...Information Rate CIR Pass Fail Threshold for Frame Loss Ratio Delay and Delay Variation Jitter 1 Tap the button to display the Local Network Settings 1 screen Select the Frame Size you wish to generate 2 Tap to display the Local Network Settings 2 screen If you are testing a VLAN set Encapsulation to VLAN and enter the VLAN ID CONFIGURE TEST Figure 4 Work Order Figure 6 Local Network Settings 2 Fi...

Страница 3: ...tion Rate CIR If the you are testing at full line rate or if traffic is not being policed uncheck the Policing checkbox 5 Tap the button twice to display the SLA Performance screen Enter the Frame Loss Ratio Frame Delay and Delay Variation pass fail criteria 6 Tap the button 5 times to display the J QuickCheck screen Figure 8 SLA Performance Figure 9 J QuickCheck Figure 7 SLA Throughput ...

Страница 4: ...ert desired Optical Transceiver into the Port 1 SFP or QSFP slot on the top of the OneAdvisor 3 If necessary insert optical attenuators into the SFP QSFP TX and or RX ports 4 Connect the SFP QSFP to the port under test using a jumper cable compatible with the line under test For Copper 10 100 1000BASE T interfaces Connect the 10 100 1000 RJ 45 jack to the port under test using CAT 5E or better cab...

Страница 5: ...m patents Contact Us To reach the VIAVI office nearest you visit viavisolutions com contact 1 844 GO VIAVI 1 844 468 4284 1 Tap the button three times to display the Report screen 2 Tap 3 Tap buttons three times to close the report and exit the Y 1564 test RUN TEST 1 Tap the button 2 Wait for the test to complete and verify that all tests pass or complete as indicated by a green or blue checkmark ...

Отзывы: