Viavi OLP-88 Скачать руководство пользователя страница 12

12

 OLP-88

2  S

AFETY

 I

NFORMATION

L

ASER

 

SAFETY

Laser safety

 WARNING

Dangerous laser radiation

Laser radiation can cause irreparable damage to eyes and 

skin. 

The maximum permitted power for the OLP-88 means that the 

optical input signals can reach hazard level.
Bear this in mind when using the OLP-88. In particular, the 

instrument is equipped with a through channel that transmits 

all the optical radiation from the input to the output without 

attenuation, even when the OLP-88 is switched off. 

Please note that also in broadband mode light is emitted at 

the unconnected port.

Always be aware of the hazard level of the instrument to be 

connected.

Connect all optical fibers before switching on the radiation 

source.

Switch off the laser source before disconnecting the optical 

fibers.

Never look directly into the unconnected port of the 

instrument, the output of a laser source, or an optical fiber 

connected to a source or a system.

Always cover unused ports.

Be aware that the emitted light is not visible.

Heed the normal precautions for working with laser radiation 

and consider local regulations.

Содержание OLP-88

Страница 1: ......

Страница 2: ...t was created General Public License This product includes Qt 4 8 3 software licensed under the GNU LGPL v 2 1 and barebox 2013 03 0 and linux 3 10 26 software licensed under the GNU GPL v 3 To request a copy of the source code for this software please write to Open Source Request Viavi Legal Department 430 N McCarthy Blvd Milpitas CA 95035 USA Copyright Copyright 2015 Viavi Solutions Inc All righ...

Страница 3: ...nt 15 Connecting optical cables 22 BASIC OPERATION 23 Switching the instrument on off 23 Operator control panel 23 Display elements 24 Navigating in the menus 25 Getting help and information 25 Configuring the instrument 26 Software options 30 TRUEPON OPERATION 32 Preparing the TruePON measurement 32 General view of the TruePON application 33 Detail views of the TruePON application 35 Edit the loc...

Страница 4: ...s 50 Displaying stored results 51 Using the Link Data Mode 52 Clearing the memory 53 MAINTENANCE 55 Cleaning the test port 55 Cleaning the instrument 56 REMOTE CONTROL 57 Communication interface 57 Command parameters and responses 60 Commands 61 Error messages 80 SPECIFICATIONS 81 Functionality 81 Technical specifications 81 General specifications 82 Patch cord microscope specifications 82 PS4 Uni...

Страница 5: ...tomatic pass fail analysis fiber end face inspection ONU ONT serial number identification and optional detection of rogue ONUs or ONTs The OLP 88 88P instruments blend a high performance λ selective FTTx PON power meter for B PON E PON G PON and automated fiber inspection and test capabilities Thanks to the automatic ODN budget class detection it provides an immediate pass fail indication and enab...

Страница 6: ... USB 2 0 and Ethernet make the SmartClass Fiber OLP 88 88P instruments even a perfect solution for fixed installations in central offices in production environments and on the laboratory workbench Common features All OLP 88 series PONmeters can connect to single mode fibers 9 125 µm Tests on systems from different manufacturers with different connector types are easy to handle due to the interchan...

Страница 7: ...independently from the burst duty cycle active idle This power meter port is calibrated at the respective center wavelength Differences between the Viavi instruments OLP 37 OLP 87 OLP 88 Supported services B PON G PON E PON X X X XG PON test capability Special version CATV Video test capability X X X RFoG test capability X X Upstream 1310nm test capability through mode X X Functions Broadband powe...

Страница 8: ...es provided by your instrument are missing please visit the Viavi web site to check if additional information is available To download the latest user manual 1 Visit the Viavi web site at http updatemyunit net 2 Select your SmartClass Fiber model from the product line 3 Open the download area and download the latest user manual Symbols used in this operating manual Various elements are used in thi...

Страница 9: ...sk of injury to persons WARNING Follow the instructions carefully to avoid servere injury to persons DANGER Follow the instructions carefully to avoid death or severe injury to persons High voltage Follow the instructions carefully to avoid damage to the instrument or severe injury to persons This safety instruction is given if the danger is due to high voltage Laser Follow the instructions carefu...

Страница 10: ...ven the numbers indicate the order in which the instructions should be followed e g Select mode Italics Result Indicates the result of following an instruction e g The page opens Boldface Pages controls and display elements Screen pages controls and display elements are indicated in boldface Text in blue Cross references Cross references are indicated in blue type When using the PDF version just c...

Страница 11: ...ase make sure the instrument is not operated outside the permitted ambient conditions Always make sure that the instrument is in proper working order before switching it on Warning symbols indicating a potential hazard In all cases where the unit is labeled with a warning symbol the operating manual must be consulted to learn more about the nature of the potential hazard and any action that must b...

Страница 12: ...nuation even when the OLP 88 is switched off Please note that also in broadband mode light is emitted at the unconnected port Always be aware of the hazard level of the instrument to be connected Connect all optical fibers before switching on the radiation source Switch off the laser source before disconnecting the optical fibers Never look directly into the unconnected port of the instrument the ...

Страница 13: ...erheating explosion or ignition of the batteries and their surround ings Never short circuit the battery contacts by touching both contacts simultaneously with an electrical conducting object Only use AA size dry batteries or rechargeable batteries Make sure the batteries are inserted with the correct polarity NOTICE Insufficient ventilation Insufficient ventilation can damage the instrument or ad...

Страница 14: ...tilation Insufficient ventilation can damage the PS4 Universal AC DC Power Supply or adversely affect its function and safety Ensure adequate ventilation when operating the PS4 Universal AC DC Power Supply NOTICE Condensation Operation in the presence of condensation can damage the PS4 Universal AC DC Power Supply or adversely affect its function and safety Do not operate the PS4 Universal AC DC P...

Страница 15: ... during shipping This is particularly likely if the packaging is visibly damaged If there is damage do not attempt to operate the instrument Doing so can cause further damage In case of damage please contact your local Viavi sales company Addresses can be found at www viavisolutions com Recovery following storage shipping Condensation can occur if a instrument that is stored or shipped at a low te...

Страница 16: ...ope PCM with FMAE adapter 2 PCM controls focus control automated Pass Fail analysis magnification control 3 Optical test ports with interchangeable test adapters 4 Test head cover green for APC and gray for PC connectors 5 3 5 inch touchscreen 6 Key pad operator control panel 7 Battery compartment and stand on rear of instrument ...

Страница 17: ...ply connector and communication inter faces 1 Optical test port 1 Downstream Connection to OLT facing side of the PON 2 Optical test port 2 Upstream Connection to ONU ONT facing side of the PON 1 Ethernet port RJ 45 2 External power supply connector 12 V 3 USB 2 0 host port Type A 4 USB 2 0 device port Type Micro B ...

Страница 18: ...tion Replacing batteries Fig 5 Replacing the batteries WARNING Dangers when handling batteries Handling batteries may be dangerous Please note the following safety instructions Please note the battery operation safety information in the chapter Battery operation on page 13 Replacing batteries Do not replace individual batteries Always change all eight batteries at the same time Always use eight ba...

Страница 19: ...e instrument The instrument switches to trickle charging automatically as soon as the RBP2 LiIon Battery Pack is fully charged Note Rechargeable AA batteries will not be recharged in the instrument For AA type rechargeable batteries please use an external charger It is not possible to charge the rechargeable AA batteries or the RBP2 LiIon Battery Pack via the USB interface The instrument is powere...

Страница 20: ...ts and other hazards Contact qualified service personnel for all service Environmental protection Please dispose of any unwanted dry batteries and rechargeable batteries carefully They should also be removed from the instrument if it is to be discarded If facilities in your country exist for collecting such waste or for recycling please make use of these rather than throwing the batteries in with ...

Страница 21: ...e plug adapter upwards 3 Slide a different AC line plug adapter into the slot see Fig 7 Fig 7 PS4 Changing the AC line plug adapter To operate the OLP 88 from AC power 1 Connect the PS4 DC power cord to the OLP 88 external power supply connector The connector is under the cover on the right side 2 Plug the PS4 into the AC line socket The OLP 88 switches on automatically when powered from the PS4 ...

Страница 22: ...y for available adapter types The OLP 88 connector type must match the cable connector type APC BN 2327 36 BN 2327 36 The PC APC versions are easily identified by the colors of the name labels on the front PC blue APC green To mount the SENKO test adapter The optical connectors are properly cleaned see Cleaning the test port on page 55 1 Open the head cover and remove the protective cap if still m...

Страница 23: ...to the homescreen Press to open menu Press to go back within an application or cancel input Press to toggle between the inspect view and the test view Press to switch the instrument on and off LED glows green when the instrument is on Press an arrow key to Navigate through the menus Change values in the menus Press the centered key to Confirm the selection Press to save results Glows red when batt...

Страница 24: ...this symbol is shown Battery status Indicates the battery charge status If it is not shown only the AC adapter is active TruePON To measure the Passive Optical Networks PON power level of 1490 1550 nm downstream or 1310 nm upstream signals to identify ONT OLT ONU to detect alien rogue ONU ONTs to test in service loss and to analyze fiber end face with auto pass fail analysis Probe To view and insp...

Страница 25: ...l or the touchscreen The following instructions describe only touchscreen operation To toggle between different display modes Tap on the display to toggle between the display modes context sensitive Getting help and information The homescreen is displayed 1 Press the A key and tap the Help button 2 To show the instrument s operating manual tap the Manual button or To show information about calibra...

Страница 26: ...he display brightness Language To select the language of the instrument texts Date Time To adjust the date date format time and to set 24 hour time or 12 hour time Date To adjust the date Date Format To adjust the date format Time To adjust the time Time Format To set 24 hour time or 12 hour time Ethernet To set the communications protocols IP Mode To select either static or DHCP Ethernet mode IP ...

Страница 27: ... and Screen Off settings are only active when no external power supply is connected Adjusting the display brightness 1 Press the A key and tap the Settings button 2 Tap the Brightness button 3 Type in the desired brightness value 4 Tap the OK button Selecting a language 1 Press the A key and tap the Settings button 2 Tap the Language button The language menu opens Remote Control Port Shows the TCP...

Страница 28: ... value 6 Tap the OK button Setting the date format 1 Press the A key and tap the Settings button 2 Tap the Date Time button 3 Tap the Date Format button 4 To change the setting tap the desired date format Setting the time 1 Press the A key and tap the Settings button 2 Tap the Date Time button 3 Tap the Time button 4 To change the setting tap the Hour Minute or Second button 5 Type in the desired ...

Страница 29: ...he desired IP address 5 Tap the OK button Setting the gateway The IP mode Static is selected 1 Press the A key and tap the Settings button 2 Tap the Ethernet button 3 Tap the Gateway button 4 Type in the desired gateway 5 Tap the OK button Setting the Wifi optional 1 Press the A key and tap the Settings button 2 Tap the Wifi button 3 Press the A key and tap the desired setting Resetting to the fac...

Страница 30: ...ars 3 Release the A key 4 Plug the USB flash drive into one of the instrument USB ports 5 To start the firmware update procedure press the center key within the arrow keys If the update procedure is terminated the instrument turns off automatically 6 Remove the USB flash drive 7 Press the E key to switch the instrument on Resetting the instrument To reset the instrument press the E key for more th...

Страница 31: ...sful installation or number of errors will be displayed in the following menu 7 Remove the USB flash drive To display the installed software options The software options are installed and the confirmation menu is displayed To show the installed software options tap the Installed Licenses button or The homescreen is displayed 1 Press the A key and tap the Software Options button 2 To show the insta...

Страница 32: ...e ODN CLASS button 4 To automatically set the ODN budget class select the Auto1 button or Select one of the predefined ODN budget classes B B C or C according to ITU T G 984 3 or Select the customizable ODN budget class User 5 Tap the LOCATION button 6 To specify the test location central office costumer site or splitter cabinet select OLT ONU ONT or a self defined location 1 Automatic ODN budget ...

Страница 33: ...ion The OLP 88 is connected with the PON network Preparing the TruePON measurement on page 32 At any network location the OLT ID is displayed Ensure that the right fiber cable is connected to the right ONT 1 Pass fail summary 2 PON ID from OLT 3 ONU ONT serial number or Alien Rogue ONT indication 4 Pass fail indicator of ODN insertion loss 5 Currently selected test location 6 Pass fail indicator o...

Страница 34: ...ected and a message is displayed that the ONU is not compliant To facilitates service recovery isolate the faulty ONU ONT and replacing it in time To perform the automatic certification Fig 10 6 7 9 To perform a power level verification at a customer ONT connect the OLP 88 to certify the service specifications The OLP 88 is connected with the PON network Preparing the TruePON measurement on page 3...

Страница 35: ...following detailed view is displayed Fig 11 GTC layer detail view To show detailed PMD Layer2 results for the different wavelengths tap the GPON U S GPON D S Video ODN Loss button A detailed view is displayed 1 G PON Transmission Convergence Layer OLT data 1 PON ID 2 Transmit Optical Level TOL 3 ODN budget class ONU ONT data 4 ONU ONT serial number 5 ONU ONT ID 2 Physical Media Dependent Layer ...

Страница 36: ... VIEWS OF THE TRUEPON APPLICATION Fig 12 PMD layer detail view Fig 13 ODN insertion loss detail view 1 Wavelength 2 Measured power 3 Margin 4 Automatically detected or manually selected ODN budget class 5 Upper threshold 6 Lower threshold ...

Страница 37: ...s the A key and tap the ADD button The desired setup is selected 6 Adjust the setup settings Description Thresholds B B C C USER Enabling the pass fail evaluation The homescreen is displayed 1 Tap the TruePON button 2 Press the A key 3 Tap the More button 4 Tap the PASS FAIL SETTINGS button 5 To enable or disable the pass fail evaluations tap on the desired button Changing the serial number format...

Страница 38: ...s the A key 3 Tap the More button 4 Tap the Measurement Data button Displaying the detailed measurement view The measurement data is displayed 1 Tap on the desired result data 2 Press the A key 3 Tap the SHOW DETAILS button The GTC Layer PMD Layer view is displayed Fig 14 GTC layer detail storage view 4 Tap on the arrows to navigate to the saved results ...

Страница 39: ...ne of the OLP 88P models with an integrated PCM for patch cord inspection and a P5000i Digital Probe for bulkhead inspection Both applications Probe and PCM behave essentially the same and are described together below Note Only if a P5000i Digital Probe is connected to the instrument is the Probe application fully functional Select an OLP 88P version in order to get PCM functionality Patch Cord Mi...

Страница 40: ...th the bulkhead female and patch cord male sides of fiber connectors as well as other optical devices such as transceivers The Digital Probe is specially designed to fit and operate comfortably and easily in hand allowing the user to inspect hard to reach connectors that are installed on the back side of patch panels or inside hardware devices In order to support a wide variety of fiber optic conn...

Страница 41: ...ee Accessories on page 84 Fig 16 P5000i Digital Probe components FBPT series tips for the P5000i The P5000i Digital Probe uses FBPT series inspection tips to ensure consistent and accurate inspection for a wide variety of connectors and applications These connector specific and universal inspection tips are interchangeable which allows the P5000i Digital Probe to interface with different types of ...

Страница 42: ...nt workflows the functionality of the QuickCapture key is configurable Pressing the key will either freeze the live image or start a test Camera mode Set the QuickCapture key on the Digital Probe to get a live picture of the result Tip Use the Focus Control key to adjust the focus of the image The Digital Probe is connected to the instrument To display the live view tap the Probe button File toolb...

Страница 43: ...he center key within the arrow keys Test mode Launching a test of the connector and fiber end face See Freeze mode on page 45 for more information on commands available To launch the test with the predefined profile see Profile on page 46 1 With the P5000i Digital Probe use the Focus Control key see Fig 16 to adjust the image quality and sharpness 2 Press the A key and tap the Test button or Press...

Страница 44: ... majority of the fiber cladding Zone C represents the epoxy ring Zone D represents the ferrule zone It identifies a portion of the ferrule near and around the fiber Note To return to a Live image press the QuickCapture key or press the A key and tap the Live button to view both the live image and a test result simultaneously If the test has been passed the image has a green colored frame If failed...

Страница 45: ... keypad enter the name of the JPG file 3 Press Enter to validate and save the document The file is saved in the current active group directory on the OLP 88 Freeze mode Once the image is acceptable sharpness luminosity are tuned correctly you may freeze the picture This feature allows you to store the resulting picture in order to compare it later to others or save it in a file In Freeze mode the ...

Страница 46: ...Fail criteria for single mode APC connectors from IEC 61300 3 35 standard SM_PC Pass Fail criteria for single mode PC connectors from IEC 61300 3 35 standard MM_ Pass Fail criteria for multi mode connectors from IEC 61300 3 35 standard SFP_ Pass Fail criteria for small form factor pluggables Profiles contain the analysis parameters from which Pass Fail criteria are determined Tip 1 Press the A key...

Страница 47: ...nts on one fiber performed with different applications can be easily assigned by the reporting software FiberChek PRO The parameters for saving or reading data can be set only globally from the homescreen menu for all applications simultaneously Non Linked Mode The result of a measurement application is saved under a free selectable file name default file name is the determined incremental prefix ...

Страница 48: ... Tap the Data Settings button 4 Tap the Create Project button to determine a new project The project appears in all available applications To delete a project The homescreen is displayed 1 Press the A key 2 Tap the Data button 3 Tap the Data Settings button 4 Tap the Delete Project button to delete a project with all assigned data The default project is always present and can t be deleted To use t...

Страница 49: ...SB Stick Tap the Export CSV to USB Stick button to export all saved data to USB drive in CSV format This file can be imported in an Excel sheet Selecting the project to save or display results All saved results are assigned to a project If the user didn t define a project the default project which is always present is used In Link Data Mode the active project can be selected only from the homepage...

Страница 50: ...ink Data Mode is not activated 1 Press the A key 2 Tap the More button 3 Tap the Measurement Data button 4 Press the A key 5 Tap the More button 6 Tap the AutoInc FiberID button to set the checkmark 7 Press the G key The Fiber ID edit menu is displayed 8 Type in the Fiber ID 9 Tap the OK button The measurement is stored 10 Press the G key again every time you want to save a an additional result va...

Страница 51: ...ected project is displayed To display the last results stored in Probe mode The homescreen is displayed 1 Tap the Data button 2 Tap the Probe button Measurement data of the currently selected project is displayed 3 Select the measurements you would like to view with the up or down arrow key and press the center key within the arrow keys to set a checkmark or To set a checkmark tap the desired meas...

Страница 52: ...The homescreen is displayed 1 Press the A key 2 Tap the Data button 3 Tap the Data Settings button 4 Tap the Create Project button 5 Type in a Project Name e g CO_MillerSt 16 6 Tap the OK button The project is created To activate the Link Data Mode The homescreen is displayed The desired project is selected 1 Press the A key 2 Tap the Data button 3 Tap the Link Data Mode button A paperclip symbol ...

Страница 53: ...d set and the date time when it was stored You do not have to clear the entire memory to free up capacity You can clear individual data or projects The OLP 88 has the following memory clear functions Delete Selected Clears the data of the selected measurement Delete Project Clears all the measurements of the selected project To clear the memory data The instrument is in application mode 1 Press th...

Страница 54: ...r all the data of a project The homescreen is displayed 1 Press the A key 2 Tap the Data button 3 Tap the Delete Project button 4 Select the project you want to delete Press the center key within the arrow keys or press the F key to cancel the delete process ...

Страница 55: ... now accessible 3 Wipe off the plug end surface using a cotton bud soaked in isopropanol This cleaning method is very effective and leaves no residue 4 Blow out the test adapter with clean compressed air available in spray cans e g anti dust spray Note Cover the optical connections with the dust cap whenever they are not in use This prevents them from getting dirty WARNING Dangerous voltage and in...

Страница 56: ...gets dirty through use you can clean it using a soft cloth moistened with a mild solution of detergent NOTICE Water and cleaning fluids The instrument may be damaged or destroyed if water or cleaning fluids penetrate it Make sure that water or cleaning fluids do not penetrate the instrument ...

Страница 57: ...al operation The main purpose of the remote control capability of the SmartClass Fiber family is to set and get Setup and Result values from an application More complex remote control commands called Extended Commands providing extended application functionality are also available In general SmartClass Fiber allows multiple applications running on the system simultaneously Hence there must be a wa...

Страница 58: ...application In order to identify an application each application has a unique application ID app_ID which will be used to set the switch For example send APPM SEL SYSTEM in order to select the system application In addition to selection via the application management commands one can use a colon followed by the app_ID as a prefix to the remote command For example add the prefix SYSTEM to any syste...

Страница 59: ...le by using the commands in the following table Note Applications that are not currently visible will return 221 Settings conflict when setting a Setup that affects shared resources Results will return an invalid value 9 91E37 NAN and most of the Extended Remote Commands will return 100 Command error Query the numerical setting range in the setup The suffixes MINV and MAXV return the minimal and m...

Страница 60: ...Integer value Examples 23 90 0 NR2 Real number Examples 23 45 1 30 NR3 Exponential number Examples 4 3E 3 8 9456E8 123E 5 NRf NR1 NR2 NR3 BOOLEAN Boolean value If the setting range is used as a response type 0 and 1 are returned Examples 0 OFF FALSE 1 ON TRUE NAN Not a number Indicates an invalid result The returned value is 9 91E37 STRING IEEE488 2 STRING_RESPONSE_DATA IEEE488 2 ...

Страница 61: ...61 COMMANDS 9 REMOTE CONTROL Commands Overview Generic commands These commands are always used without a prefix IDN OPT RST APPM LIST APPM SEL APPM SEL APPM VER SYST DATE SYST DATE SYST ERR SYST TIME SYST TIME ...

Страница 62: ...ONE A F INSP ZONE NUMB APP ID VSBL APP ID VSBL AUTO CNTR AUTO CNTR CAPT BTTN MODE CAPT BTTN MODE FQM ENAB FQM ENAB FRZE BUSY INSP BUSY INSP ERR INSP PRF NAME INSP PRF NAME INSP PRF NAMES INSP TBL SHOW INSP TBL SHOW INSP TIP NAME INSP TIP NAME INSP TIP NAMES MAGN HIGH MAGN HIGH MICR BAD MICR CON MICR DET MICR OPER MODE MICR OPER MODE OVRL SHOW OVRL SHOW STOR AUTO INCR ENAB STOR AUTO INCR ENAB STOR ...

Страница 63: ... STOR NAMES STOR NOTE STOR NOTE STOR WR BUSY APP FACT DEF MICR CAL INFO MICR MODL NAME MICR SER NUMB MICR SW VER STOR ALL DEL STOR DEL STOR GRP CREA STOR GRP DEL STOR EVAL TYPE STOR RD STOR RD EVAL XML STOR RD FMAP STOR RD IMG HIGH STOR RD IMG HIGH OVRL STOR RD IMG LOW STOR RD IMG LOW OVRL STOR WR ...

Страница 64: ...l see also Operating manual update on page 8 SYSTEM application These commands are used with the prefix SYSTEM Setups Extended commands APP ID VSBL APP ID VSBL AUTO OFF AUTO OFF DISP BRGH DISP BRGH DISP OFF DISP OFF ETH MAC ADDR IP ADDR IP ADDR STAT IP ADDR STAT IP GATE IP GATE STAT IP GATE STAT IP MASK IP MASK STAT IP MASK STAT IP MODE IP MODE LANG LANG OPT INST BUSY OPT INST ERR LIST OPT INST LI...

Страница 65: ...OLP 88 65 COMMANDS 9 REMOTE CONTROL PowerManagement application These commands are used with the prefix PMGNT Results Setups Extended commands BATT CAP PERC BATT TYPE POW SPLY CON STOR AVLB APP FACT DEF ...

Страница 66: ...ST Provides a list of application IDs separated by commas Response type STRING_RESPONSE_DATA APPM SEL STRING Selects the application specified by the application ID provided Valid values All application IDs returned from APPM LIST APPM SEL Returns the application ID of the currently selected application APPM VER Returns the version of the remote control application SYST DATE Sets the system date y...

Страница 67: ...the image Response type NR1 FQM PERC MAX Focus quality highwater mark Highest focus quality value recently observed Response type NR1 INSP PASS Pass Fail result for the complete fiber Response type BOOLEAN INSP PASS ZONE A F Pass Fail result for fiber zones A F respectively depending on the selection Response type BOOLEAN INSP ZONE NUMB Number of available inspection zones Response type NR1 ...

Страница 68: ...for more information AUTO CNTR BOOLEAN Controls fiber center tracking for live video images in high magnification mode Default TRUE AUTO CNTR Returns TRUE if the fiber center tracking in live video is turned on Response type BOOLEAN See AUTO CNTR command for more information CAPT BTTN MODE NR1 Controls the function of the probes capture button Valid values 0 Freeze 1 Test Default 1 CAPT BTTN MODE ...

Страница 69: ...efault name See INSP PRF NAMES command for more information INSP PRF NAME Returns the name of the selected inspection profile Response type STRING See INSP PRF NAME command for more information INSP PRF NAMES Returns the names of all available inspection profiles read from common PCM and MSCOPE profile directory INSP TBL SHOW BOOLEAN Shows or hides the result table for a tested image Default TRUE ...

Страница 70: ... of the Digital Probe is high Response type BOOLEAN See MAGN HIGH command for more information MICR BAD Returns TRUE if the detected Digital Probe could not be initialized properly Response type BOOLEAN MICR CON Returns TRUE if a Digital Probe is detected and the authorization as well as initialization tasks have finished successfully Response type BOOLEAN MICR DET Returns TRUE if a Digital Probe ...

Страница 71: ...nt feature Valid range 1 to maximum integer Default 1 STOR AUTO INCR IDX Returns the current index for the automatic increment feature Response type NR1 See STOR AUTO INCR IDX command for more information STOR AUTO INCR PRFX STRING Sets the prefix for the automatic increment feature STOR AUTO INCR PRFX Returns the prefix for the automatic increment feature Response type STRING See STOR AUTO INCR P...

Страница 72: ...ype Unit Info Command string Parameter type Response type Unit Info APP FACT DEF Sets all parameters of the application to their default values MICR CAL INFO Returns the list of calibrations tips of the connected Digital Probe Example of a list sf supported fibers PCM 2 active calibrations 0 Standard Tips with BAP1 sf 1 1 Ribbon Tips sf 2 MICR MODL NAME Returns the model of the connected Digital P...

Страница 73: ...entifier string3 STOR RD EVAL XML STRING STRING STRING Returns the contents of a pfr xml pfr pass fail result file specified by group string1 fiber identifier string2 and internal identifier string3 Special format h 3104 696e7072cdcc STOR RD FMAP STRING STRING STRING Returns the contents of a fmap pgm gz fmap pgm gz feature map portable gray map gzip file specified by group string1 fiber identifie...

Страница 74: ...ts of a tlm jpg tlm jpg test low magnification jpg file specified by group string1 fiber identifier string2 and internal identifier string3 Special format h 16100 696e7072cdcc STOR WR STRING STRING Writes a dedicated measurement result specified by group string1 and fiber identifier string2 If the given group doesn t exist it will be created This command can take a few seconds to complete Wait unt...

Страница 75: ...esponse type STRING See APP ID VSBL command for more information AUTO OFF NR1 Sets the time of inactivity after which the instrument automatically goes into standby mode If an external power supply is connected the instrument doesn t enter standby mode Valid values 0 5 min 1 10 min 2 20 min 3 30 min 4 Never Default 2 AUTO OFF Returns the time of inactivity after which the instrument automatically ...

Страница 76: ...y valid for the instrument In static mode this setup corresponds to IP ADDR STAT in DHCP mode it is provided by the DHCP server This setup is read only IP ADDR STAT STRING Sets the static mode IP address IP ADDR STAT Returns the static mode IP address Response type STRING See IP ADDR STAT command for more information IP GATE Returns the IP gateway address which is currently valid for the instrumen...

Страница 77: ... if the IP address should be requested by DHCP or a static address should be used Valid values 0 STATIC 1 DHCP Default 1 IP MODE Returns whether the instrument is set to a static or dynamic IP address Response type NR1 See IP MODE command for more information LANG NR1 Sets the user interface language Valid values 0 en_US 1 de_DE 2 fr_FR 3 es_ES 4 zh_CN 5 zh_TW Default 0 LANG Returns which user int...

Страница 78: ...rns a list of the software options installed via USB flash drive or a key The list is cleared at the beginning of each installation OPT ULCK Returns all installed software options STOR AVLB Returns whether the application can or cannot store measurements Always FALSE for SYSTEM application Command string Parameter type Response type Unit Info Command string Parameter type Response type Unit Info A...

Страница 79: ...t an internal battery NOBATT with a rechargeable Lithium Ion battery LIION or with standard dry cell batteries DRYCELL 0 No battery 1 Lithium Ion battery 2 Dry cell batteries POW SPLY CON 0 No external power supply is connected 1 An external power supply is connected Command string Parameter type Response type Unit Info STOR AVLB Returns whether the application can or cannot store measurements Alw...

Страница 80: ...ystem error 350 Queue overflow 360 Communication error 100 Command error 101 Invalid character 108 Parameter not allowed 109 Missing parameter 110 Command header error 112 Program mnemonic too long 113 Undefined header 220 Parameter error 221 Settings conflict 222 Data out of range 224 Illegal parameter value 254 Media full 290 Memory use error ...

Страница 81: ...obe OLP 88P version Via integrated patch cord microscope 1 For B PON ITU T G 983 E PON IEEE 802 3 G PON ITU T G 984 signals 2 Optional with or G PON signals according ITU T G 984 3 Amendment 3 3 For G PON signals according ITU T G 984 without PON ID Power measurements Upstream 1310 nm1 Power measurement range 40 to 13 dBm Maximum permitted input level 17 dBm Spectral passband 1290 to 1330 nm Downs...

Страница 82: ...plug for EU UK US and AU Battery Li Ion Battery Pack 3 7 V 20 Wh Battery life Li Ion Battery Pack 12 h Optical connectors Interchangeable adapter SC APC optional FC ST and LC adapters Recommended recalibration interval 3 years Size H x W x D OLP 88 208 x 112 x 64 mm 8 2 x 4 4 x 2 5 in Size H x W x D OLP 88P 208 x 153 x 64 mm 8 2 x 6 0 x 2 5 in Weight 750 g 850 g 1 6 lbs 1 85 lbs Operating temperat...

Страница 83: ...4 Universal AC DC Power Supply Condensation even occasional is not tolerable Power supply type FW 75550 12 Nominal line voltage range 100 to 240 VAC Nominal line frequency range 47 to 63 Hz Power consumption Max 8 5 W Output 12 V DC 2 A Temperature range 0 to 40 C ...

Страница 84: ...P 88 TruePON Tester BN 2327 36 1310 1490 1550 nm OLP 88P TruePON Tester with Patchcord Microscope BN 2328 36 WiFi option including USB WiFi adapter BN 2327 90 11 P5000i Digital Probe with FiberChek PRO software and four tips FBP P5000I OLP 88 Alien ONT detection SW option BN 2327 94 01 OLP 88 GPON ID test SW option BN 2327 94 02 PS4 Universal AC DC Power Supply for SmartClass Fiber BN 2305 90 01 R...

Страница 85: ...ing 15 Default values 29 Device overview 16 Differences between the devices 6 Display elements 24 E Environmental Management Program 87 Environmental protection 20 Extended commands 79 Probe PCM 72 System 78 F Factory default 29 Firmware update 30 L Laser safety 12 Link Data Mode 24 52 M Menu Configuration 26 Menu navigation 25 N Navigating in the menus 25 O On Off 23 Operation Probe PCM 39 TruePO...

Страница 86: ...robe PCM 67 TruePON 74 RoHS 89 S Saving results 50 Selective power measurements 6 Setups 79 Probe PCM 68 System 75 Shipping damage 15 Specifications 81 FTTx measurements 81 Functionality 81 General 82 Technical specifications 81 Symbols used 8 System 64 T Test adapter mounting 22 Through path 7 TruePON 64 74 Detail view 35 General view 33 Location threshold settings 37 Measurement view 38 Pass fai...

Страница 87: ...facture Environmental restrictions and requirements are taken into account during planning and manufacture of Viavi products This attention ranges from the raw materials and finished components selected for use and the manufacturing processes employed through to the use of energy in the factory and right on up to the final stages in the life of a product including dismantling Hazardous materials V...

Страница 88: ...of a crossed out trash can and a black bar This symbol can be found either on the device or in the accompanying documents Contact your local Technical Assistance Center TAC for return and collection services available to you If you would like specific information about the Viavi Environmental Management Program please contact us at If you would like specific information about the Viavi Environment...

Страница 89: ...㒥 揜ↅ 㦘䤓㦘㹡ᇬ 㦘 䓸德ₜ 㒥㽓䆞ᇭ年㦮棟ₜ抑䞷ℝ庇Ⱁ䟄㻯 㢢劦 ᇭ 㦘 㷲デ㝜 㧰ↅ 庆 屐ℶ 䞷㓆㓚 ᇭ ℶ 䞮ℶ㡴㦮庆 屐ℶ 䤓 ⱚ㪰 幐 ᇭ 䅃ℛ啾搩 PBDE O O O O O O 䅃勣啾 PBB O O O O O O ↆ杻 CR6 O O O O O O 柘 Cd O O O O O O 㻭 Hg O O O O O O 㦘㹡ᇬ㦘 䓸德 侯 杔 Pb X O O O O O 㦘㹡ᇬ㦘 䓸德䤓伊 㓏 捷ↅ ↅ Component ℶ Main Product Ⓠ䟄恾㨎兓ↅ PCB Assemblies 捷揜兎 Internal wiring 㣍䯉 Display 枽䥧 Keyboard 㠨 榅ↅ Plastic case parts 揜ↅ Accessories O ⅲ嫷年捷 㓏㦘 德㧟㠨 㦘䤓年㦘㹡ᇬ㦘 䓸德 摞 ℝSJ T11363 2006㪖 䤓棟 ᇭ X ⅲ嫷年...

Страница 90: ......

Отзывы: