To perform BER analysis of a circuit
1
Configure the instrument. For details, see:
–
“Specifying interface settings” on page 12
–
“Specifying the timing settings” on page 13
–
“Specifying data settings” on page 14
–
“Specifying signal and flow control settings” on page 15
–
“Selecting a BER pattern” on page 16
–
“Defining user programmable patterns” on page 19
2
If this is the first test you are performing today, perform a self-test (see
Performing a self test” on page 7
3
Connect to the circuit under test (see
“Step 3: Connecting the instrument to the
4
Start the test (see
“Step 4: Starting the test” on page 8
).
5
Verify that the PATTERN SYNC LED is illuminated.
6
Insert the error (or errors) using the
Error Insert
action button.
7
Observe the test results, particularly the results in the BERT and the G.821 cate-
gories (see
“Step 5: Viewing test results” on page 9
).
BER analysis is complete.
Measuring round trip delay
Measuring round trip delay involves selecting the
R-TRIP DELAY
BER pattern, config-
uring the remaining settings for the test, connecting to the circuit, starting the test, and
then viewing test results. When you start the test, the instrument inserts 16 consecutive
bit errors into the transmitted
R-TRIP DELAY
pattern, and then measures the amount
of time (in milliseconds) before 16 consecutive bit errors are detected on the received
R-TRIP DELAY
pattern.
The scenario below provides the basic steps involved; you may need to configure addi-
tional settings for your particular circuit.
To measure round trip delay
1
Configure the instrument. For details, see:
–
“Specifying interface settings” on page 12
–
“Specifying the timing settings” on page 13
–
“Specifying data settings” on page 14
–
“Specifying signal and flow control settings” on page 15
2
Select the R-TRIP DELAY pattern (see
“Selecting a BER pattern” on page 16
3
If this is the first test you are performing today, perform a self-test (see
Содержание MSAM
Страница 2: ......
Страница 10: ...Contents Data Communications and Diphase Testing Manual Page viii 21148872 Rev 002 January 2016 ...
Страница 68: ...Glossary Data Communications and Diphase Testing Manual Page 52 21148872 Rev 002 January 2016 ...
Страница 72: ...Index Data Communications and Diphase Testing Manual Page 56 21148872 Rev 002 January 2016 ...
Страница 73: ......