background image

 

 

  

 

 

 

 

   

VIAVI Solutions

 

Quick Card 

 

T-BERD

®

/MTS-5800 Modular Test Set

  

E4100-series OTDR SMART TEST 

 
This quick card describes how to connect to a fiber under test, configure 

SMART TEST

 OTDR settings, 

run tests, and analyze results with a VIAVI T-BERD/MTS-5800 and 4100-series OTDR module.  
 

Equipment Requirements: 

 

T-BERD/MTS-5800 equipped with the following: 

o

 

Fiber Optics Software Release V17.22 or 
greater 

o

 

E4100 Series OTDR Module 

 

Fiber optic cleaning and inspection tools 

 

Launch Cable with connectors matching the 
OTDR port and Fiber Under Test (a 20-meter 
Fiber optic patch cable or leash is recommended) 

 

Optical Coupler to connect Launch Cable to Fiber 
Under Test 

 

 

Figure 1: Equipment Requirements

 

The following information is required to complete the 
test: 

 

Type of Fiber (Multimode or Single Mode) 

 

Type of Connectors (SC UPC, SC APC, LC UPC, etc.) 

 

Distance unit (feet, meters, miles, kilometers) 

 

 

Fiber Inspection Guidelines: 

 

Use the VIAVI P5000i or FiberChek Probe 
microscope to inspect both sides of every 
connection being used (OTDR Port, Launch Cable, 
bulkhead connectors, patch cords, etc.) 

 

Focus the fiber on the screen.  If dirty, clean the 
connector. 

 

If it appears clean, run inspection test. 

 

If it fails, clean the fiber and re-run inspection 
test.  Repeat until it passes.

 

 

 

Figure 2: Inspect Before You Connect (IBYC)

 

Connect Launch Cable to OTDR port: 

1.

 

Inspect the OTDR port on top of the test set.  

2.

 

Inspect the fiber end face of Launch Cable. 

3.

 

Connect Launch Cable to the OTDR port. 

 

 

Содержание E4100 Series

Страница 1: ...unch Cable to Fiber Under Test Figure 1 Equipment Requirements The following information is required to complete the test Type of Fiber Multimode or Single Mode Type of Connectors SC UPC SC APC LC UPC etc Distance unit feet meters miles kilometers Fiber Inspection Guidelines Use the VIAVI P5000i or FiberChek Probe microscope to inspect both sides of every connection being used OTDR Port Launch Cab...

Страница 2: ...rn dark blue 7 Distance Unit Tap the desired unit of measure for the launch cable 8 Launch Cable Tap YES if you are using a Launch Cable Tap the icon to enter or measure the Launch Cable length If the launch cable length is known tap to clear existing text enter new value on the keypad and tap to return To measure the launch cable length tap Measure and tap Confirm The measured value will auto pop...

Страница 3: ...t the launch cable repeat steps 1 through 3 on page 1 and repeat steps 1 through 4 above on page 3 2 The T BERD will perform acquisitions at the configured wavelengths 3 Results can be displayed in 2 different formats Trace view or SmartLink view Tap to toggle between views Figure 9 Connection Check SmartLink view The FUT is displayed as a series of icons representing each event connectors splices...

Страница 4: ... zoom controls Toggle between automatic zoom and full trace view Expand and contract trace Figure 11 Trace View 4 Tap the Save softkey to view File Recording Information 5 Enter Fiber Id Fiber Number Locations and Job ID as follows Tap field to open keyboard Tap to clear existing text Enter desired value Tap icon to return Note The Job ID field identifies the Job ID and creates a folder to save th...

Отзывы: