CT-X User’s Guide
22137813, Rev. 000
Feb 2020
30
Chapter
2 Setting up Your CT-X
Measuring adjacent channels
The channels adjacent to the soon-to-be-enabled signals were measured and the data is
reflected below.
Left channel
Signal
Right channel
ID
Power
(dBmV)
MER
(dB)
Freq
(MHz)
Freq
(MHz)
Power
(dBmV)
MER
(dB)
Freq
(MHz)
1
25.4
34.9
135
138
25.9
35.1
141
2
26.0
34.9
381
384
---
---
---
3
26.2
---
531
540
---
---
---
4
---
---
---
750
25.3
38.4
753
1) Signals 2 and 4 only had one adjacent channel. That channel will be used for
proving no interference.
2) Signal 3 had no adjacent channels, so we will use the closest channel but skip
the interference check.
NOTE:
If a signal is set up without any adjacent signals, and at a
later time additional signals are placed into the channel
lineup that become adjacent, it will be necessary to re-run
the MER measurement as if it were there to begin with.
Содержание CT-X
Страница 1: ...CT X Advanced Leakage Tagger User s Guide ...
Страница 4: ...CT X User s Guide 22137813 Rev 000 Feb 2020 4 ...
Страница 40: ...CT X User s Guide 22137813 Rev 000 Feb 2020 40 Chapter 2 Setting up Your CT X ...
Страница 45: ......