![Viavi CellAdvisor JD700B Series Скачать руководство пользователя страница 319](http://html.mh-extra.com/html/viavi/celladvisor-jd700b-series/celladvisor-jd700b-series_user-manual_1011747319.webp)
Chapter 9
Using LTE-TDD Signal Analyzer
318
JD700B Series User’s Guide
Performing auto measurements
Conformance test
The Conformance Test is to test if eNode-B meets some specified standards that have been developed for
verification. Its test procedure and test setups have been developed by 3GPP. Test results can be saved as
a
.csv
file type.
Setting limit for conformance test
You can set test limits for test item(s) in the auto measurement. Turning the test limit on for a test item
makes the test item included in the conformance test.
Procedure
1
Press the
LIMIT
hot key.
2
To set the limit for BTS output power, complete the following steps:
Press the
BTS Output Power
soft key.
Toggle the
Test Limits
soft key between
On
and
Off
to enable or disable the limit.
Press the
High Limit
soft key.
Enter a value for the upper limit, and then press the
dBm
unit soft key.
Press the
Low Limit
soft key.
Enter a value for the lower limit, and then press the
dBm
unit soft key.
3
To set the limit for total power dynamic, complete the following steps:
Press the
Total Power Dynamic
soft key.
Toggle the
Test Limits
soft key between
On
and
Off
to enable or disable the limit.
Press the
Low Limit
soft key.
Enter a value for the lower limit, and then press the
dBm
unit soft key.
4
To set the limit for on/off power, press the
On/Off Power
soft key, and then do the following as
needed:
To set the limit for
Select
Set
Off power
Off Power
High Limit
Transition period
Transition Period
High Limit
5
To verify signal quality, press the
Signal Quality
soft key, and then do the following as needed:
To set the limit for
Select
Set
Frequency error
Frequency Error
High Limit, Low Limit
Error vector magnitude
EVM
High Limit (QPSK)
High Limit (16 QAM)
High Limit (64 QAM)
Time alignment error
Time Alignment Error
High Limit
RS power
RS Power
High Limit, Low Limit
6
To verify unwanted emissions, press the
Unwanted Emissions
soft key, and then do the
following as needed:
To set the limit for
Select
Set
Occupied bandwidth
Occupied BW
High Limit
Adjacent channel power ratio
ACLR
Spectrum emission mask
SEM
Mask Type
Содержание CellAdvisor JD700B Series
Страница 2: ...CellAdvisorTM JD700B Series FW3 120 User s Guide ...
Страница 105: ...Chapter 4 Using Spectrum Analyzer 104 JD700B Series User s Guide Figure 44 PIM detection for multiple carriers ...
Страница 406: ...Chapter 11 Using EV DO Signal Analyzer JD700B Series User s Guide 405 3 Pilot 4 MAC 64 5 MAC 128 ...
Страница 734: ...Chapter 18 Perfroming BBU Emulation JD700B Series User s Guide 733 Figure 441 Example of verification of link status ...
Страница 763: ...Chapter 21 Performing Fiber Inspection 762 JD700B Series User s Guide Figure 461 Fiber inspection report ...
Страница 808: ...Appendix JD700B Series User s Guide 807 JD740B series ...
Страница 811: ...Appendix 810 JD700B Series User s Guide Figure 470 Append keywords window ...