Using Real-time Spectrum Analyzer
82
Persistent spectrum
The persistent spectrum of a signal is a time-frequency view that shows the percentage of the time that a given frequency is present
in a signal. It is a histogram in power-frequency space. The longer a particular frequency persists in a signal as the signal evolves,
the higher its time percentage and thus the brighter or hotter its color in the display. The persistent spectrum is used to identify
signals hidden in other signals.
Setting measure setup for Sound Indicator
If you have configured test parameters as described in the "
Configuring Spectrum Measurements
", continue to set measure setup.
You can simply change Center Frequency and Span by tapping the icons right below the result chart screen.
1
Tap the
Setup
(
) icon on the side bar.
2
Tap
Sound Indicator
.
a
Tap to switch the
Sound
between
On
and
Off
to enable and disable the alarm sound.
b
Tap to switch the
Alarm Reference
to
Marker
to set the active marker position as the alarm reference.
c
Tap to switch the
Alarm Reference
to
Line
to set the limit as the alarm reference.
The Reference Line Mode menu becomes activated to be set.
d
Select
Reference Line
to specify a threshold for the reference line using the on-screen keyboard.
e
Optional.
To adjust the volume for alarm sound, tap
Volume
and input from 1 to 10 using the on-screen keyboard.
Setting measure setup for Interference ID
The Interference ID automatically classifies interfering signals over a designated spectrum and displays the list of possible signal
types corresponding to the selected signal.
1
Tap the
Setup
(
) icon on the side bar.
2
Tap
Interference
ID
.
a
Tap to switch the
Interference
ID
between
On
and
Off
to turn the Interference ID on and off.
b
Tap
Threshold
and input a value using the on-screen keyboard.
Setting measure setup for POI
The Interference ID automatically classifies interfering signals over a designated spectrum and displays the list of possible signal
types corresponding to the selected signal.
1
Tap the
Setup
(
) icon on the side bar.
2
Tap
POI
. You can also access this menu via Quick Access and Display Tab on top.
a
Tap to switch the
Mode
between
High
and
Normal
.
The following table shows RBW and Span setup range per Normal and High mode.
Mode
A
B
C
D
Normal
POI
100 to 34 μs
392 to 136.5 μs
800.5 to 270.5 μs
3200 to 1076 μs
Bandwidth
100 to 20 MHz
19 to 5 MHz
4 and 3 MHz
2 and 1 MHz
RBW
30 kHz to 10 MHz
10 kHz to 1 MHz
3 kHz to 1 MHz
1 kHz to 300 kHz
Mode
A
B
C
D
E
F
High
POI
18.5 to 2.5
μs
29.5 to
4 μs
73.5 to 7.5
μs
147 to 15 μs
284 to 28 μs
587 to 56.5
μs
Содержание CellAdvisor 5G
Страница 1: ...1 CellAdvisorTM 5G User s Guide ...
Страница 2: ......
Страница 18: ......
Страница 22: ......
Страница 110: ......
Страница 146: ......
Страница 182: ...Using LTE LTE A TDD Analyzer 170 CCDF measurement with LTE LTE A TDD Analyzer ...
Страница 264: ......
Страница 312: ......
Страница 332: ......
Страница 338: ......
Страница 346: ...Using RFoCPRI Analyzer 334 Rx Settings with RFoCPRI Analyzer ...
Страница 352: ......
Страница 356: ...Appendix 344 ...
Страница 357: ...345 ...
Страница 358: ......